Suppr超能文献

开放式奶牛舍气体浓度监测采样点水平分布分析

Analysis of the Horizontal Distribution of Sampling Points for Gas Concentrations Monitoring in an Open-Sided Dairy Barn.

作者信息

D'Urso Provvidenza Rita, Arcidiacono Claudia, Cascone Giovanni

机构信息

Department of Agriculture, Food and Environment (Di3A)-Building and Land Engineering Section, University of Catania, Via Santa Sofia n° 100, 95123 Catania, Italy.

出版信息

Animals (Basel). 2022 Nov 23;12(23):3258. doi: 10.3390/ani12233258.

Abstract

In the livestock sector, the monitoring of gas concentrations plays a relevant role in the implementation of mitigation strategies, as well as the improvement in the indoor air quality for both workers and animals in barns. In the present study, measurements of gas concentrations (NH3, CH4, and CO2) at different locations were carried out in an open dairy barn using a commercial photo-acoustic spectroscopy system. Measurement variability for different datasets was computed to contribute to the evaluation of the sampling strategy in the measurement campaign. The results showed that the position of sampling locations (SLs) significantly influenced (p < 0.001) the variability in the gas distribution. Specifically, the SLs located on the perimeter of the building had the highest variability. The number of SLs utilised for determining the mean value of gas concentration in the barn had a significant influence on NH3 (p < 0.001), CO2 (p < 0.001), and CH4 (p < 0.001) in both the central zone and the perimeter one. At least three SLs were necessary to obtain a mean value of gas concentration that reduced the variability to under the 10% in the central zone and 16% in the perimeter one. Moreover, the NH3 concentrations obtained as the mean value of the gas measurements at two SLs with a 10 m distance had a lower variability compared to those recorded at two SLs located at 5 m.

摘要

在畜牧部门,气体浓度监测在实施减排策略以及改善畜舍内工人和动物的室内空气质量方面发挥着重要作用。在本研究中,使用商用光声光谱系统在一个开放式奶牛场的不同位置进行了气体浓度(NH₃、CH₄和CO₂)测量。计算了不同数据集的测量变异性,以有助于评估测量活动中的采样策略。结果表明,采样位置(SLs)的位置对气体分布的变异性有显著影响(p < 0.001)。具体而言,位于建筑物周边的SLs变异性最高。用于确定畜舍内气体浓度平均值的SLs数量对中心区域和周边区域的NH₃(p < 0.001)、CO₂(p < 0.001)和CH₄(p < 0.001)均有显著影响。在中心区域,至少需要三个SLs才能获得将变异性降低到10%以下的气体浓度平均值,在周边区域则为16%。此外,作为在两个相距10 m的SLs处进行气体测量的平均值获得的NH₃浓度,其变异性低于在两个相距5 m的SLs处记录的变异性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9dd9/9736405/f132cf5ae079/animals-12-03258-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验