Suppr超能文献

基于磁共振成像的动脉结构的后循环缺血的有效机械取栓。

Effective Mechanical Thrombectomy for Posterior Circulation Ischemia Using Magnetic Resonance Imaging-based Arterial Structures.

机构信息

Department of Neurosurgery, Tenri Hospital.

出版信息

Neurol Med Chir (Tokyo). 2023 Mar 15;63(3):122-126. doi: 10.2176/jns-nmc.2022-0246. Epub 2023 Jan 20.

Abstract

To improve the success of mechanical thrombectomy, three-dimensional turbo spin-echo (3D-TSE) sequences on T2WI can be employed to estimate the vascular structure of the posterior circulation. In addition to the short imaging time of 3D-TSE T2WI (33 sec), it can visualize the outer diameter of the main cerebral artery, including the occluded vessels. However, to date, the efficacy of mechanical thrombectomy in the posterior circulation remains unclear, and safer and more efficient mechanical thrombectomy procedures are required. Assessment of the anatomical variations in the posterior circulation using 3D-TSE T2WI is valuable for access decisions, device selection, and safe device guidance and retrieval techniques to the target vessel. Herein, we present representative cases of basilar artery and posterior cerebral artery occlusions in our institute and describe the utility of preoperative 3D-TSE T2WI in these patients.

摘要

为提高机械取栓的成功率,可以采用三维涡轮自旋回波(3D-TSE)序列 T2WI 来评估后循环的血管结构。除了 3D-TSE T2WI(33 秒)的成像时间短之外,它还可以显示大脑主要动脉的外径,包括闭塞的血管。然而,迄今为止,机械取栓在后循环中的疗效仍不清楚,需要更安全、更有效的机械取栓方法。使用 3D-TSE T2WI 评估后循环的解剖变异对于进入决策、器械选择以及安全的器械引导和向目标血管取回技术都具有重要价值。在此,我们展示了我院基底动脉和大脑后动脉闭塞的典型病例,并描述了术前 3D-TSE T2WI 在这些患者中的应用。