Suppr超能文献

Xpert MTB/RIF 检测经内镜超声引导针吸活检技术诊断纵隔结核性淋巴结炎的系统评价和荟萃分析。

Xpert MTB/RIF in the Diagnosis of Mediastinal Tuberculous Lymphadenitis by Endoscopic Ultrasound-Guided Needle Aspiration Techniques: A Systematic Review and Meta-Analysis.

机构信息

Respiratory Unit, ASST Santi Paolo e Carlo, Department of Health Sciences, Università degli Studi di Milano, Milan, Italy.

Clinical Epidemiology and Medical Statistics Unit, Department of Medical, Surgical, Experimental Sciences, University of Sassari, Sassari, Italy.

出版信息

Respiration. 2023;102(3):237-246. doi: 10.1159/000528947. Epub 2023 Jan 24.

Abstract

BACKGROUND

Lymphadenopathy is one of the most prevalent clinical manifestations of extrapulmonary tuberculosis. Endosonography is the recommended technique in the diagnostic work-up of mediastinal lymphadenopathies. Xpert MTB/RIF assay is a self-contained cartridge-based fully automated DNA testing platform which can accurately detect both tuberculosis and mycobacterial resistance to rifampicin. A few studies assessed its accuracy for mediastinal lymph node aspirates collected using endosonography. A systematic review of observational studies was performed to provide a pooled estimate of sensitivity and specificity of Xpert MTB/RIF in the diagnosis of mediastinal tuberculous lymphadenitis using endoscopic ultrasound-guided needle aspiration techniques.

METHODS

A search of the scientific evidence was carried out using PubMed, Embase, and Scopus. Articles describing observational studies on Xpert MTB/RIF in the diagnosis of mediastinal tuberculous lymphadenitis using endoscopic ultrasound-guided needle aspiration techniques were selected.

RESULTS

Eight studies met the inclusion criteria. The overall pooled sensitivity was 61% (95% CI = 55-68%; I2 = 66.3%; p = 0.004), overall pooled specificity was 89% (95% CI = 85-91%; I2 = 90.1%; p < 0.0001). Area under the sROC curve was 0.68. Only one study reported data on rifampin resistance detection and showed a sensitivity of 83.3% and a specificity of 16%.

CONCLUSIONS

Xpert MTB/RIF shows a good accuracy in the diagnosis of mediastinal mycobacterial lymphadenitis by endosonographic needle aspiration techniques. It should be always recommended for suspected mediastinal tuberculosis.

摘要

背景

淋巴结病是肺外结核最常见的临床表现之一。超声内镜检查是纵隔淋巴结病诊断性检查的推荐技术。Xpert MTB/RIF 检测是一种基于试剂盒的全自动 DNA 检测平台,可准确检测结核分枝杆菌和利福平耐药性。有几项研究评估了其在超声内镜引导下经皮穿刺纵隔淋巴结抽吸物中的准确性。本系统评价旨在通过观察性研究,提供 Xpert MTB/RIF 对超声内镜引导下经皮穿刺技术诊断纵隔结核性淋巴结炎的敏感性和特异性的综合估计值。

方法

使用 PubMed、Embase 和 Scopus 进行了科学证据检索。选择描述 Xpert MTB/RIF 在超声内镜引导下经皮穿刺技术诊断纵隔结核性淋巴结炎的观察性研究的文章。

结果

八项研究符合纳入标准。总的汇总敏感性为 61%(95%CI=55-68%;I2=66.3%;p=0.004),总的汇总特异性为 89%(95%CI=85-91%;I2=90.1%;p<0.0001)。sROC 曲线下面积为 0.68。仅有一项研究报告了利福平耐药检测的数据,显示敏感性为 83.3%,特异性为 16%。

结论

Xpert MTB/RIF 在经超声内镜引导下经皮穿刺技术诊断纵隔分枝杆菌淋巴结炎方面具有良好的准确性。对于疑似纵隔结核,应始终推荐使用。