Cai Xingbo, Wang Bin, Zhang Bihuan, Zhang Yue, Wang Teng, Lin Wei, Huang Youjun, Chen Bingquan, Zhou Siyuan, Lu Sheng, Xu Yongqing
Graduate School, Kunming Medical University, Kunming, China.
Department of Orthopedics, 920th Hospital of Joint Logistics Support Force, PLA, Kunming, China.
Front Bioeng Biotechnol. 2023 Jan 10;10:1119720. doi: 10.3389/fbioe.2022.1119720. eCollection 2022.
Total wrist arthroplasty is an effective treatment for end-stage wrist arthritis from all causes. However, wrist prostheses are still prone to complications such as prosthesis loosening and periprosthetic fractures after total wrist arthroplasty. This may be due to the wrist prosthesis imprecise matching with patient's bone. In this study, we designed and developed a personalized three-dimensional printed microporous titanium artificial wrist prosthesis (3DMT-Wrist) for the treatment of end-stage wrist joint, and investigated its safety and effectiveness. Total wrist arthroplasty was performed using 3DMT-Wrist in 14 cases of arthritis between February 2019 and December 2021. Preoperative and postoperative visual analog scale scores, QuickDASH scores, wrist range of motion, and wrist grip strength were evaluated. Data were statistically analyzed using the paired samples -test. After 19.7 ± 10.7 months of follow-up, visual analog scale decreased from 66.3 ± 8.9 to 6.7 ± 4.4, QuickDASH scores decreased from 47.4 ± 7.3 to 28.2 ± 7.6, grip strength increased from 5.6 ± 1.4 to 17.0 ± 3.3 kg. The range of motion improved significantly in palmar flexion (30.1° ± 4.9° to 44.9° ± 6.5°), dorsal extension (15.7° ± 3.9° to 25.8° ± 3.3°), ulnar deviation (12.2° ± 3.9° to 20.2° ± 4.3°) and radial deviation (8.2° ± 2.3° to 16.2 ± 3.1). No dislocation or loosening of the prosthetic wrist joint was observed. Total wrist arthroplasty using 3DMT-Wrist is a safe and effective new treatment for various types of end-stage wrist arthritis; it offers excellent pain relief and maintains the range of motion.
全腕关节置换术是治疗各种病因所致终末期腕关节炎的有效方法。然而,全腕关节置换术后腕关节假体仍易出现假体松动和假体周围骨折等并发症。这可能是由于腕关节假体与患者骨骼的匹配不准确。在本研究中,我们设计并开发了一种用于治疗终末期腕关节的个性化三维打印微孔钛人工腕关节假体(3DMT-Wrist),并对其安全性和有效性进行了研究。2019年2月至2021年12月期间,使用3DMT-Wrist对14例关节炎患者进行了全腕关节置换术。评估了术前和术后视觉模拟评分、QuickDASH评分、腕关节活动范围和握力。使用配对样本检验对数据进行统计学分析。随访19.7±10.7个月后,视觉模拟评分从66.3±8.9降至6.7±4.4,QuickDASH评分从47.4±7.3降至28.2±7.6,握力从5.6±1.4增加至17.0±3.3千克。掌屈(从30.1°±4.9°至44.9°±6.5°)、背伸(从15.7°±3.9°至25.8°±3.3°)、尺偏(从12.2°±3.9°至20.2°±4.3°)和桡偏(从8.2°±2.3°至16.2±3.1°)的活动范围均有显著改善。未观察到人工腕关节脱位或松动。使用3DMT-Wrist进行全腕关节置换术是治疗各种类型终末期腕关节炎的一种安全有效的新方法;它能有效缓解疼痛并维持活动范围。