Suppr超能文献

在经导管主动脉瓣置入术(TAVI)术前计算机断层扫描血管造影中采用双流技术进行超低容量造影剂-生理盐水混合注射的可行性

Feasibility of Ultra-Low Volume Contrast-Saline Mixture Injection With Dual-Flow Technique in a Pre-TAVI Computed Tomography Angiography.

作者信息

Gallo Giuseppe S, Caruso Calogero, Iannazzo Erica, Cannataci Christine, Gerasia Roberta, Tafaro Corrado, Gentile Giovanni, Mamone Giuseppe, Caruso Settimo, Marrone Gianluca, Gandolfo Caterina, Miraglia Roberto

机构信息

Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy.

Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS-ISMETT), Palermo, Italy.

出版信息

Heart Lung Circ. 2023 Apr;32(4):525-534. doi: 10.1016/j.hlc.2022.12.013. Epub 2023 Feb 17.

Abstract

BACKGROUND

To explore the feasibility and image quality of ultra-low volume contrast-saline mixture injection with dual-flow injection technique in a computed tomography angiography (CTA) protocol in patients scheduled for transcatheter aortic valve implantation (TAVI).

METHODS

Forty (40) TAVI candidates underwent investigation with CTA using a third-generation dual-source CT scanner between September and November 2020. Different volumes of a monophasic contrast-saline mixture at an 80:20 ratio were administered at an infusion rate of 3 mL/s in 20 patients (group A). The injected volume was based on patient body mass index (BMI): 50 mL if BMI <29 kg/m and 63 mL if BMI >29 kg/m. The other 20 patients (group B)-the control cases-received a total of 65 mL of contrast medium (CM), in multiphasic injections at different flow rates, followed by 10 mL of saline. The images that were obtained were prospectively evaluated for image quality, vessel attenuation (HU), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and estimated radiation dose.

RESULTS

Image quality of the aortic root and ilio-femoral vessels was diagnostic in all patients. Vascular attenuation was >200 HU and CNR >3 at any vessel level.

CONCLUSIONS

Data from this study suggest that a monophasic ultra-low volume contrast-saline mixture injection with a dual-flow technique can provide clear visualisation of the aortic root and ilio-femoral vessels in pre-TAVI CTA, which is comparable with a standard multiphasic volume injection protocol.

摘要

背景

探讨在计划行经导管主动脉瓣植入术(TAVI)的患者的计算机断层血管造影(CTA)方案中,采用双流注射技术进行超低容量对比剂 - 盐水混合液注射的可行性和图像质量。

方法

2020年9月至11月期间,40例TAVI候选患者使用第三代双源CT扫描仪接受CTA检查。20例患者(A组)以3 mL/s的输注速率给予不同体积的80:20单相对比剂 - 盐水混合液。注射体积基于患者体重指数(BMI):BMI<29 kg/m²时为50 mL,BMI>29 kg/m²时为63 mL。另外20例患者(B组)——对照组——共接受65 mL对比剂,以不同流速进行多相注射,随后注射10 mL盐水。对获得的图像进行前瞻性评估,评估内容包括图像质量、血管衰减(HU)、信噪比(SNR)、对比噪声比(CNR)和估计辐射剂量。

结果

所有患者的主动脉根部和髂股血管的图像质量均具有诊断价值。在任何血管水平,血管衰减均>200 HU,CNR>3。

结论

本研究数据表明,采用双流技术的单相超低容量对比剂 - 盐水混合液注射可在TAVI术前CTA中清晰显示主动脉根部和髂股血管,与标准多相容量注射方案相当。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验