近视眼角膜屈光手术后 6 个月的角膜上皮重塑。

Corneal Epithelial Remodeling in a 6-Month Follow-up Period in Myopic Corneal Refractive Surgeries.

出版信息

J Refract Surg. 2023 Mar;39(3):187-196. doi: 10.3928/1081597X-20230113-02. Epub 2023 Mar 1.

Abstract

PURPOSE

To investigate corneal epithelial thickness changes during a 6-month follow-up period after transepithelial photorefractive keratectomy (tPRK), femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK), and small incision lenticule extraction (SMILE).

METHODS

This prospective study included 76 eyes of 76 participants who underwent myopic refractive surgery (23 FS-LASIK, 22 SMILE, and 31 tPRK). Epithelial thickness and anterior curvature were averaged over 4 regions (subdivided into 25 areas) and measured by spectral-domain optical coherence tomography and Scheimpflug tomography before the operation (pre) and at 1 or 3 days (pos1-3d), 1 week (pos1w), and 1 month (pos1m), 3 months (pos3m), and 6 months (pos6m) postoperatively.

RESULTS

The epithelial thickness of the three groups was similar in both the pre and pos6m (all > .05), but the tPRK group fluctuated the most during the follow-up period. The largest increase was in the inferior-temporal paracentral area (7.25 ± 2.58 μm for FS-LASIK; 5.79 ± 2.41 μm for SMILE; 4.88 ± 5.84 μm for tPRK; all < .001). Only the epithelial thickness of tPRK increased from pos3m to pos6m ( < .05), whereas all changes for FS-LASIK and SMILE were not significant ( > .05). A positive correlation of thickness changes with curvature gradient in the paracentral region of tPRK was found ( = 0.549, = .018), but not in other regions in all groups.

CONCLUSIONS

Epithelial remodeling followed different trends after different surgeries from the early postoperative stage onward, but exhibited similar values at pos6m. Although remodeling after FS-LASIK and SMILE stabilized by pos3m, it remained unstable at pos6m after tPRK. These changes may affect corneal profile and lead to deviation from the intended surgical outcome. .

摘要

目的

研究经上皮准分子激光角膜切削术(tPRK)、飞秒激光辅助准分子原位角膜磨镶术(FS-LASIK)和小切口角膜透镜取出术(SMILE)术后 6 个月内角膜上皮厚度的变化。

方法

本前瞻性研究纳入 76 名(76 只眼)接受近视屈光手术的患者,其中 23 例行 FS-LASIK、22 例行 SMILE、31 例行 tPRK。采用频域光学相干断层扫描仪和 Scheimpflug 断层扫描仪分别在术前(pre)和术后 1 或 3 天(pos1-3d)、1 周(pos1w)、1 个月(pos1m)、3 个月(pos3m)和 6 个月(pos6m)测量 4 个区域(细分为 25 个区)的上皮厚度和前曲率。

结果

三组患者的上皮厚度在术前和术后 6 个月时均相似(均 >.05),但 tPRK 组在随访期间波动最大。下颞旁中心区的上皮厚度增加最明显(FS-LASIK 为 7.25 ± 2.58 μm;SMILE 为 5.79 ± 2.41 μm;tPRK 为 4.88 ± 5.84 μm;均 <.001)。仅 tPRK 组的上皮厚度从 pos3m 到 pos6m 增加( <.05),而 FS-LASIK 和 SMILE 的所有变化均无统计学意义( >.05)。在 tPRK 的旁中心区,厚度变化与曲率梯度呈正相关( = 0.549, =.018),但在各组的其他区域则无相关性。

结论

不同手术的上皮重塑从术后早期开始呈现不同的趋势,但在术后 6 个月时表现出相似的数值。尽管 FS-LASIK 和 SMILE 的重塑在 pos3m 时趋于稳定,但 tPRK 术后 6 个月时仍不稳定。这些变化可能会影响角膜形态,导致与预期手术结果的偏差。