Abstract

OBJECTIVE

To evaluate the accuracy of a 3-dimensionally (3D)-printed custom endoscopy port (3DEP) for minimally invasive cervical ventral slot decompression.

STUDY DESIGN

Cadaveric study.

ANIMALS

Fifteen cadavers of dogs weighing between 3.1 and 34.4 kg.

METHODS

Minimally invasive cervical ventral slots were created using a 3DEP and an endoscopic system at the C3-C4 intervertebral disc space in each dog by 1 experienced and 1 inexperienced surgeon. Postoperative computed tomography was performed to compare the planned and postoperative screw trajectories (angle, entry point, exit point, and length of the screw entering the spinal canal) and quantify slot formation dimensions.

RESULTS

Thirty screws were inserted in 30 vertebral bodies. Mean screw angle deviation was less than 2.5°, entry and exit point deviation was less than 1.6 mm, and length of the screw entering the spinal canal was less than 0.6 mm. No differences were identified between the experienced and inexperienced surgeons. Ventral slot length ratio was 30.15 ± 1.86 for the experienced surgeon and 29.38 ± 1.61 for the inexperienced surgeon (p = .372). The mean ventral slot width ratio was 45.60 ± 1.80 for the experienced surgeon and 47.20 ± 1.54 for the inexperienced surgeon (p = .261).

CONCLUSION

Screw positioning and creation of ventral slots were accurately performed using the 3DEP by both inexperienced and experienced surgeons.

CLINICAL SIGNIFICANCE

The use of a 3DEP for minimally invasive cervical ventral slot decompression may be an alternative to the conventional ventral slot in dogs. Additional studies are needed to evaluate efficacy and safety.

摘要

目的

评估 3 维打印定制内镜端口(3DEP)在微创颈椎前路开槽减压术中的准确性。

研究设计

尸体研究。

动物

15 只体重 3.1 至 34.4 公斤的犬尸体。

方法

通过 1 名有经验的外科医生和 1 名无经验的外科医生,在每只犬的 C3-C4 椎间盘水平,使用 3DEP 和内镜系统创建微创颈椎前路开槽。术后行计算机断层扫描,比较规划和术后螺钉轨迹(角度、进钉点、出钉点和进入椎管的螺钉长度),并量化开槽形成尺寸。

结果

30 个螺钉被插入 30 个椎体。平均螺钉角度偏差小于 2.5°,进钉点和出钉点偏差小于 1.6mm,进入椎管的螺钉长度小于 0.6mm。有经验和无经验的外科医生之间没有差异。有经验的外科医生的前槽长度比为 30.15±1.86,无经验的外科医生为 29.38±1.61(p=0.372)。有经验的外科医生的前槽宽度比平均为 45.60±1.80,无经验的外科医生为 47.20±1.54(p=0.261)。

结论

有经验和无经验的外科医生均能使用 3DEP 准确进行螺钉定位和前槽开槽。

临床意义

在犬中,使用 3DEP 进行微创颈椎前路开槽减压术可能是传统前路开槽的替代方法。需要进一步的研究来评估其疗效和安全性。