Suppr超能文献

小儿脑脊液漏内镜治疗的浴塞技术

Bath-plug technique for the endoscopic management of cerebrospinal fluid leaks in children.

作者信息

Yang Xiaojian, Tang Lixing, Wang Pengpeng, Ge Ming, Zhang Wei, Xiao Xiao, Han Yang, Ge Wentong

机构信息

Department of Otorhinolaryngology, Head and Neck Surgery Beijing Children's Hospital Capital Medical University National Center for Children's Health Beijing China.

Department of Neurosurgery Beijing Children's Hospital Capital Medical University National Center for Children's Health Beijing China.

出版信息

Pediatr Investig. 2022 Nov 22;7(1):23-28. doi: 10.1002/ped4.12354. eCollection 2023 Mar.

Abstract

IMPORTANCE

The safety and efficacy of the bath-plug technique for the closure of cerebrospinal fluid (CSF) leaks in children remain unknown.

OBJECTIVE

We undertook this study to ascertain whether the bath-plug technique was safe and effective for the repair of CSF leaks.

METHODS

We retrospectively reviewed patients who underwent endoscopic repair of CSF leaks with the fat graft as a plug-in at Beijing Children's Hospital from March 2016 to May 2020. Demographic data, medical history, defect sites and sizes, interventions, and clinical outcomes were analyzed. One representative clinical case was additionally selected to highlight the procedure and the healing process.

RESULTS

A total of 18 pediatric patients were included in this study. The group was composed of 11 boys and seven girls, aged from 5 to 123 months. The etiologies included congenital CSF leaks ( = 9) and head trauma ( = 9). Among all patients, 12 fistulas (66.7%) were located at the cribriform plate area, two (11.1%) at the roof of the ethmoid sinuses, two (11.1%) in the sphenoid sinus, and two (11.1%) at the frontal sinus. The maximum diameters of fistulas ranged from 5 to 20 mm, with a median value of 8 mm. Encephaloceles were identified in 14 (77.8%) patients. No hydrocephalus was recognized. All CSF leaks were successfully repaired with a bath-plug technique. Follow-up ranged from 50 to 70 months. No surgical complications were encountered in any patient.

INTERPRETATION

Bath-plug technique is safe and reliable for the endoscopic management of CSF leaks in children. Meticulous peri-operative preparations are important for pediatric patients.

摘要

重要性

浴栓技术用于儿童脑脊液(CSF)漏封堵的安全性和有效性尚不清楚。

目的

我们开展本研究以确定浴栓技术修复CSF漏是否安全有效。

方法

我们回顾性分析了2016年3月至2020年5月在北京儿童医院接受内镜下用脂肪移植作为栓塞物修复CSF漏的患者。分析了人口统计学数据、病史、缺损部位和大小、干预措施及临床结局。另外选取1例有代表性的临床病例以突出该手术过程及愈合过程。

结果

本研究共纳入18例儿科患者。该组由11名男孩和7名女孩组成,年龄从5个月至123个月。病因包括先天性CSF漏(9例)和头部外伤(9例)。所有患者中,12处瘘口(66.7%)位于筛板区域,2处(11.1%)位于筛窦顶部,2处(11.1%)位于蝶窦,2处(11.1%)位于额窦。瘘口最大直径为5至20毫米,中位数为8毫米。14例(77.8%)患者发现有脑膨出。未发现脑积水。所有CSF漏均采用浴栓技术成功修复。随访时间为50至70个月。所有患者均未出现手术并发症。

解读

浴栓技术用于儿童CSF漏的内镜治疗安全可靠。精心的围手术期准备对儿科患者很重要。