Graefes Arch Clin Exp Ophthalmol. 2023 Sep;261(9):2557-2565. doi: 10.1007/s00417-023-06046-9. Epub 2023 Apr 1.
This study aimed to evaluate the visual performance and rotational stability of the multifocal toric intraocular lens in myopes.
This prospective, observational study included patients with an axial length of ≥24.5 mm and regular corneal astigmatism of >1 diopter who underwent phacoemulsification cataract surgery and implantation of a multifocal toric intraocular lens (AT LISA toric 909M). The visual acuity, defocus curves, residual astigmatism, rotational stability, higher-order aberrations (HOAs), modulation transfer function (MTF), spectacle dependence and patient satisfaction were evaluated 3 months after surgery.
Forty-three eyes from 30 patients were enrolled in this study. Postoperatively, uncorrected distance and near visual acuities (logMAR) were 0.09 ± 0.08 (standard deviation, SD) and 0.14 ± 0.08, respectively. The defocus curve analysis provided a bimodal curve showing two peaks of maximum vision at 0.0 D and at -3.0 D defocus level. The multifocal toric intraocular lens showed excellent rotational stability; the mean rotation was 4.02 ± 2.49 (SD) degrees at 3 months postoperatively. Refractive predictability was excellent with a mean spherical equivalent of 0.19 ± 0.37 (SD) diopters (D) and a mean refractive cylinder of -0.34 ± 0.39 (SD) D.
The diffractive multifocal toric intraocular lens, AT LISA toric 909M, provided effective distance and near visual acuities in myopic eyes. It was a predictable and effective device with good rotational stability for the correction of preexisting astigmatism during cataract surgery. In this study, more than 80% of patients achieved spectacle independence.
本研究旨在评估远视患者多焦点散光型人工晶状体的视觉性能和旋转稳定性。
这是一项前瞻性、观察性研究,纳入了眼轴长度≥24.5mm 且角膜规则散光>1 屈光度的患者,这些患者接受了超声乳化白内障吸除术,并植入了多焦点散光型人工晶状体(AT LISA toric 909M)。术后 3 个月评估患者的视力、离焦曲线、残余散光、旋转稳定性、高阶像差(HOAs)、调制传递函数(MTF)、对眼镜的依赖性和患者满意度。
本研究纳入了 30 名患者的 43 只眼。术后,未矫正远视力和近视力(logMAR)分别为 0.09±0.08(标准差,SD)和 0.14±0.08。离焦曲线分析显示,双模式曲线在 0.0D 和-3.0D 离焦水平有两个最大视力的峰值。多焦点散光型人工晶状体具有出色的旋转稳定性;术后 3 个月平均旋转度为 4.02±2.49(SD)度。预测屈光效果良好,平均等效球镜为 0.19±0.37(SD)屈光度(D),平均屈光柱镜为-0.34±0.39(SD)D。
散光型多焦点人工晶状体 AT LISA toric 909M 为远视眼提供了有效的远距和近距视力。作为白内障手术中矫正原有散光的一种可预测且有效的设备,它具有良好的旋转稳定性。在本研究中,超过 80%的患者达到了不戴眼镜的视力。