Following breast augmentation, 100 patients with inflatable saline implants were followed for a period of 6 months to 8 1/2 years. Capsular contracture rate, Baker II or greater, was 3.4 percent. This low rate of capsular contracture is attributed to early manipulation of the implant. The deflation rate was also 3.4 percent. The Heyer-Schulte (Mentor) inflatable implant offers an acceptable low rate of leakage to justify its continued use. It also offers an advantage in correction of asymmetries and yields softer breasts. The replacement of an occasional deflated implant does not appear to pose more than a minor nuisance nor to materially compromise the possibility of an excellent long-term result.

摘要

相似文献

1
Clinical experience with Heyer-Schulte inflatable implants in breast augmentation.
Plast Reconstr Surg. 1986 May;77(5):772-8. doi: 10.1097/00006534-198605000-00014.
2
Experience with 326 inflatable breast implants.
Plast Reconstr Surg. 1994 Jan;93(1):118-22. doi: 10.1097/00006534-199401000-00017.
4
Treatment of the firm augmented breast by capsular stripping and inflatable implant exchange.
Plast Reconstr Surg. 1977 Nov;60(5):720-4. doi: 10.1097/00006534-197711000-00007.
5
Capsular contracture after breast reconstruction with silicone-gel and saline-filled implants: a 6-year follow-up.
Plast Reconstr Surg. 1990 Mar;85(3):373-7. doi: 10.1097/00006534-199003000-00006.
6
Long term results of inflatable mammary implants.
Br J Plast Surg. 1995 Jun;48(4):183-8. doi: 10.1016/0007-1226(95)90000-4.
8
Long-term use of polyurethane breast prostheses: a 14-year experience.
Plast Reconstr Surg. 1990 Aug;86(2):368-71. doi: 10.1097/00006534-199008000-00033.
9
[10 years results following augmentation-plasty].
Helv Chir Acta. 1989 Apr;55(6):879-86.
10
Satisfactions and dissatisfactions of patients with augmentation mammaplasty.
Plast Reconstr Surg. 1979 Aug;64(2):151-5. doi: 10.1097/00006534-197908000-00003.

引用本文的文献

2
Augmentation mammaplasty using implants: a review.
Arch Plast Surg. 2012 Sep;39(5):448-51. doi: 10.5999/aps.2012.39.5.448. Epub 2012 Sep 12.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验