Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, Oita, Japan.
Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, Oita, Japan.
J Orthop Sci. 2024 May;29(3):741-748. doi: 10.1016/j.jos.2023.03.019. Epub 2023 Apr 10.
This study aimed to study the accuracy of pedicle screw (PS) insertion into dysplastic pedicles in adolescent idiopathic scoliosis (AIS) comparing cannulated screw using the pedicle expansion technique (PET) versus conventional technique.
Forty-two AIS patients with 766 PSs were evaluated. In total, 236 screws were inserted into dysplastic pedicles: 138 and 98 screws were inserted using the PET (PET group) and standard technique (conventional group), respectively. Both methods used CT-based navigation to determine the insertion point. In the PET, a rigid ball tip feeler was tapped with a mallet to create an insertion route, a guide wire was passed through the tap, the pedicle was enlarged, and then a cannulated PS with a diameter of 4.35 mm was inserted. Postoperative CT was used to compare the accuracy of PS insertion.
In total, 23/236 (9.7%) perforations occurred. Regarding overall perforation, there were six (4.3%) and 17 (17.3%) cases in the PET and conventional group, respectively (P = 0.008). In terms of medial perforation, the PET group (n = 2, 1.4%) was significantly better than the conventional group (n = 7, 7.1%) (P = 0.021). In terms of lateral perforation, the PET group (n = 4, 2.9%) was significantly better than conventional group (n = 10, 10.2%) (P = 0.030). Only grade 1 perforation had occurred in the PET group, whereas grades 2 and 3 perforation occurred in the conventional group.
Use of the PET with CT-based navigation significantly increased the accuracy and safety of PS insertion in dysplastic pedicles in AIS.
本研究旨在比较经皮扩张技术(PET)与传统技术,评估在青少年特发性脊柱侧凸(AIS)中使用空心螺钉(PS)置入发育不良椎弓根的准确性。
共评估了 42 例 AIS 患者的 766 个 PS。总共 236 个螺钉被置入发育不良的椎弓根:138 个和 98 个螺钉分别使用 PET(PET 组)和标准技术(常规组)插入。两种方法均使用基于 CT 的导航确定插入点。在 PET 中,使用刚性球头探子敲击,用锤子敲击以创建插入路径,导丝穿过探子,扩大椎弓根,然后插入直径为 4.35mm 的空心 PS。使用术后 CT 比较 PS 插入的准确性。
总共发生了 23/236(9.7%)个穿孔。关于总体穿孔,PET 组和常规组分别有 6(4.3%)和 17(17.3%)例(P=0.008)。关于内侧穿孔,PET 组(n=2,1.4%)明显优于常规组(n=7,7.1%)(P=0.021)。关于外侧穿孔,PET 组(n=4,2.9%)明显优于常规组(n=10,10.2%)(P=0.030)。只有 PET 组发生了 1 级穿孔,而常规组发生了 2 级和 3 级穿孔。
使用 CT 导航的 PET 显著提高了 AIS 发育不良椎弓根中 PS 插入的准确性和安全性。