文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

用于主动脉瓣钙化定量的三维计算机断层扫描重建工具的验证

Validation of a Three-Dimensional Computed Tomography Reconstruction Tool for Aortic Valve Calcium Quantification.

作者信息

Hokken Thijmen W, Ooms Joris F, Kardys Isabella, Hirsch Alexander, Weustink Annick C, Schipper Sanne, Heil Peter, Daemen Joost, Budde Ricardo P J, Van Mieghem Nicolas M

机构信息

Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, the Netherlands.

Department of Radiology and Nuclear Medicine, Erasmus University Medical Center, Rotterdam, the Netherlands.

出版信息

Struct Heart. 2022 Nov 28;7(2):100122. doi: 10.1016/j.shj.2022.100122. eCollection 2023 Mar.


DOI:10.1016/j.shj.2022.100122
PMID:37275588
原文链接:https://pmc.ncbi.nlm.nih.gov/articles/PMC10236772/
Abstract

BACKGROUND: Aortic valve calcification correlates with the severity of aortic valve stenosis and a high calcium score is associated with conduction disturbances and paravalvular leakage after transcatheter aortic valve replacement. The 3mensio Structural Heart is a semiautomated software package to facilitate aortic root analysis by multislice computed tomography.The aim of the contemporary study is to validate a semiautomated calcium quantification scoring tool with a conventional manual calcium quantification tool. METHODS: Fifty randomly selected patients who underwent multislice computed tomography for preprocedural planning were retrospectively selected to compare the semiautomated aortic valve Agatston calcium score by 3mensio with the manually obtained score using IntelliSpace Portal as standard reference. RESULTS: Patients had a mean age of 76.7 ± 7.4 years and 60% were male. The median Agatston score was 3390 [interquartile range 1877-4509] with 3mensio and 3434 [interquartile range 1839-4620] with IntelliSpace.The mean difference was -0.18 [95% confidence interval (CI) -53.8 to 53.4]. The intraclass correlation coefficient between the Agatston scores using IntelliSpace and 3mensio showed an excellent correlation of 0.995 [95% CI 0.992-0.997], ≤ 0.001. The interobserver and intraobserver variability was 0.993 ([95% CI 0.961-0.998], ≤ 0.001) and 0.995([95%CI 0.981-0.999], = <0.001), respectively. CONCLUSIONS: The semiautomated calcium quantification module in 3mensio Structural Heart highly correlated with a conventional manual calcium scoring tool.

摘要

背景:主动脉瓣钙化与主动脉瓣狭窄的严重程度相关,高钙评分与经导管主动脉瓣置换术后的传导障碍和瓣周漏有关。3mensio结构心脏是一个半自动软件包,可通过多层计算机断层扫描促进主动脉根部分析。本当代研究的目的是用传统的手动钙定量工具验证一种半自动钙定量评分工具。 方法:回顾性选取50例因术前规划而接受多层计算机断层扫描的患者,以使用IntelliSpace Portal手动获得的分数作为标准参考,比较3mensio半自动主动脉瓣阿加斯顿钙评分。 结果:患者的平均年龄为76.7±7.4岁,60%为男性。使用3mensio时阿加斯顿评分的中位数为3390[四分位间距1877 - 4509],使用IntelliSpace时为3434[四分位间距1839 - 4620]。平均差异为-0.18[95%置信区间(CI)-53.8至53.4]。使用IntelliSpace和3mensio的阿加斯顿评分之间的组内相关系数显示出0.995[95%CI 0.992 - 0.997]的极佳相关性,P≤0.001。观察者间和观察者内的变异性分别为0.993([95%CI 0.961 - 0.998],P≤0.001)和0.995([95%CI 0.981 - 0.999],P<0.001)。 结论:3mensio结构心脏中的半自动钙定量模块与传统的手动钙评分工具高度相关。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba1e/10236772/a49d7ead031d/gr2.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba1e/10236772/2b009e67bee5/gr1.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba1e/10236772/a49d7ead031d/gr2.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba1e/10236772/2b009e67bee5/gr1.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba1e/10236772/a49d7ead031d/gr2.jpg

相似文献

[1]
Validation of a Three-Dimensional Computed Tomography Reconstruction Tool for Aortic Valve Calcium Quantification.

Struct Heart. 2022-11-28

[2]
Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation.

JACC Cardiovasc Interv. 2013-8-14

[3]
Accuracy and reproducibility of aortic annulus sizing using a dedicated three-dimensional computed tomography reconstruction tool in patients evaluated for transcatheter aortic valve replacement.

EuroIntervention. 2014-7

[4]
[Anythink for CT-based aorta root measurements before transcatheter aortic valve replacement: measurement consistency with 3mensio and impact on short-term prognosis].

Nan Fang Yi Ke Da Xue Xue Bao. 2022-11-20

[5]
Feasibility, Accuracy, and Reproducibility of Aortic Annular and Root Sizing for Transcatheter Aortic Valve Replacement Using Novel Automated Three-Dimensional Echocardiographic Software: Comparison with Multi-Detector Row Computed Tomography.

J Am Soc Echocardiogr. 2017-11-23

[6]
Automated assessment of the aortic root dimensions with multidetector row computed tomography.

Ann Thorac Surg. 2011-3

[7]
Clinical utility of intraprocedural three-dimensional integrated image guided transcatheter aortic valve implantation using novel automated computed tomography software: A single-center preliminary experience.

Catheter Cardiovasc Interv. 2018-11-8

[8]
Quantification of aortic valve calcification using multislice spiral computed tomography: comparison with atomic absorption spectroscopy.

Invest Radiol. 2006-5

[9]
Reproducibility of aortic valve calcification scoring with computed tomography - An interplatform analysis.

J Cardiovasc Comput Tomogr. 2019-1-16

[10]
Threshold for calcium volume evaluation in patients with aortic valve stenosis: correlation with Agatston score.

J Cardiovasc Med (Hagerstown). 2021-6-1

引用本文的文献

[1]
Gated Computed Tomography Evaluation of the Aortic Root for Treatment Planning of Patients With Aortic Stenosis.

J Soc Cardiovasc Angiogr Interv. 2024-3-26

[2]
Aortic Valve Calcium Score: Applications in Clinical Practice and Scientific Research-A Narrative Review.

J Clin Med. 2024-7-11

本文引用的文献

[1]
Transcatheter aortic valve implantation: current status and future perspectives.

Eur Heart J. 2018-7-21

[2]
2017 ESC/EACTS Guidelines for the management of valvular heart disease.

Eur Heart J. 2017-9-21

[3]
Relation between calcium burden, echocardiographic stent frame eccentricity and paravalvular leakage after corevalve transcatheter aortic valve implantation.

Eur Heart J Cardiovasc Imaging. 2017-6-1

[4]
Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation.

Eur Heart J Cardiovasc Imaging. 2016-1-12

[5]
Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis.

J Am Coll Cardiol. 2014-7-15

[6]
Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation.

JACC Cardiovasc Interv. 2013-8-14

[7]
Aortic stenosis in the elderly: disease prevalence and number of candidates for transcatheter aortic valve replacement: a meta-analysis and modeling study.

J Am Coll Cardiol. 2013-5-30

[8]
The 3mensio Valves™ multimodality workstation.

EuroIntervention. 2012-4

[9]
Aortic valve calcium score as a predictor for outcome after TAVI using the CoreValve revalving system.

Int J Cardiol. 2011-12-22

[10]
Epidemiology of valvular heart disease in the adult.

Nat Rev Cardiol. 2011-1-25

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索