Abstract

BACKGROUND AND STUDY AIMS

The single-operator cholangiopancreatoscopy (SOCP) with the SpyGlass™ system is a endoscopy technique whose use has grown exponentially in recent years. The aims of this study were to evaluate the efficacy and safety of SOCP with SpyGlass™ and determine the factors related to the onset of adverse events (AEs).

PATIENTS AND METHODS

Retrospective study at a single tertiary institution with inclusion of all consecutive patients undergoing SOCP with SpyGlass™ from February-2009 to December-2021. No exclusion criteria were considered. A descriptive statistical analysis was performed. The factors associated with the existence of AE were analyzed using Chi-square and Student's t-test.

RESULTS

A total of 95 cases were included. The most common indications were biliary strictures (BS) evaluation (66.3%) or treatment of difficult common bile duct stones (27.4%). Technical and clinical success was attained in 98.9%. Single-session stone clearance was obtained in 84%. The AE rate was 7.4%. To detect malignancy in BS, optical diagnosis presents a sensitivity and specificity of 100% and 91.2%, respectively; while histology results were 36.4% and 100% respectively. A previous endoscopic sphincterotomy was associated with a lower rate of AEs (2.4% vs 41.7%; p<0.001).

CONCLUSIONS

SOCP with SpyGlass™ is a safe and effective technique to diagnose and treat pancreatobiliary pathology. The presence of sphincterotomy performed prior to the procedure could improve the technique's safety.

摘要

背景与研究目的

使用SpyGlass™系统的单人操作胆管胰管镜检查(SOCP)是一种近年来应用呈指数级增长的内镜技术。本研究的目的是评估使用SpyGlass™进行SOCP的有效性和安全性,并确定与不良事件(AE)发生相关的因素。

患者与方法

在一家单一的三级医疗机构进行回顾性研究,纳入2009年2月至2021年12月期间所有连续接受使用SpyGlass™进行SOCP的患者。未考虑排除标准。进行描述性统计分析。使用卡方检验和学生t检验分析与AE存在相关的因素。

结果

共纳入95例病例。最常见的适应证是胆管狭窄(BS)评估(66.3%)或治疗困难的胆总管结石(27.4%)。技术成功率和临床成功率达到98.9%。单次结石清除率为84%。AE发生率为7.4%。为检测BS中的恶性肿瘤,光学诊断的敏感性和特异性分别为100%和91.2%;而组织学结果分别为36.4%和100%。既往内镜括约肌切开术与较低的AE发生率相关(2.4%对41.7%;p<0.001)。

结论

使用SpyGlass™进行SOCP是诊断和治疗胰胆疾病的一种安全有效的技术。术前进行括约肌切开术可提高该技术的安全性。