Suppr超能文献

超声测量尺侧副韧带的可靠性:一项多评估者前瞻性研究。

Reliability of sonographic measurements of the ulnar collateral ligament: a multi-rater prospective study.

机构信息

Marieb College of Health & Human Services Office of the Dean, Florida Gulf Coast University, Fort Myers, FL, United States of America.

Department of Rehabilitation Sciences, Florida Gulf Coast University, Fort Myers, FL, United States of America.

出版信息

PeerJ. 2023 Jun 6;11:e15418. doi: 10.7717/peerj.15418. eCollection 2023.

Abstract

BACKGROUND

The use of sonography is a cost-effective and reliable method to evaluate upper extremity superficial tissue structural integrity and pathology. Establishing the measurement reliability of widely used diagnostic ultrasound evaluation for musculoskeletal assessment is paramount enhance accurate clinical evaluations. The objective of this study was to establish the inter-rater and intra-rater reliability of select ulnar collateral ligament (UCL) thickness measures at two distinct anatomical locations in intercollegiate baseball athletes using ultrasound imaging (USI).

METHODS

This was a prospective cohort study conducted in a university research laboratory and included a total of 17 NCAA Division I baseball athletes (age 20.4 ± 1.43, height = 183.63 cm ± 6.27 cm, mass = 89.28 kg ± 8.24 kg). Two trained clinicians measured UCL mid-substance and apex thickness in the throwing extremity, prospectively, on 5 occasions at 1-month intervals during rest. Intraclass correlation coefficients (ICCs) (model 3,3), associated standard error of measurement, and 95% minimal detectable change in thickness were derived.

RESULTS

Intrarater reliability estimates for operator 1 were 0.90-0.98 (mid-substance) and 0.91-0.99 (apex). Operator 2's values were 0.92-0.97 and 0.93-0.99, respectively. The standard error of measurement (SEM) ranged from 0.045-0.071 cm (mid-substance) and 0.023-0.067 cm (apex). The minimal detectable difference (MDD95) was 0.12-0.20 cm (mid-substance) and 0.07-0.19 cm (apex). Interrater reliability was 0.86-0.96 (mid-substance) and 0.79-0.98 (apex); most ICCs were >0.90. Measurement of UCL thickness at two locations demonstrated very good to excellent reliability with high precision. Using this protocol, two evaluators can obtain consistent UCL measurement at two positions. This finding has significant implications for the clinical evaluation of superficial tissue pathology of the same individual by two experienced practitioners.

摘要

背景

超声检查是一种经济有效的可靠方法,可用于评估上肢浅表组织结构的完整性和病变。建立广泛应用于肌肉骨骼评估的诊断超声评估的测量可靠性对于提高准确的临床评估至关重要。本研究的目的是使用超声成像(USI)在大学运动医学实验室中建立两个不同解剖位置的大学生棒球运动员尺侧副韧带(UCL)厚度的测量的组内和组间可靠性。

方法

这是一项前瞻性队列研究,共纳入 17 名 NCAA 一级棒球运动员(年龄 20.4 ± 1.43 岁,身高 = 183.63 cm ± 6.27 cm,体重 = 89.28 kg ± 8.24 kg)。两名经过培训的临床医生在休息时以 1 个月的间隔前瞻性地测量 5 次投掷侧 UCL 中部和尖端的厚度。得出组内相关系数(ICC)(模型 3,3)、测量的标准误差和厚度的 95%最小可检测变化。

结果

操作者 1 的组内可靠性估计值为 0.90-0.98(中部)和 0.91-0.99(尖端)。操作者 2 的值分别为 0.92-0.97 和 0.93-0.99。测量的标准误差(SEM)范围为 0.045-0.071 cm(中部)和 0.023-0.067 cm(尖端)。最小可检测差异(MDD95)为 0.12-0.20 cm(中部)和 0.07-0.19 cm(尖端)。组间可靠性为 0.86-0.96(中部)和 0.79-0.98(尖端);大多数 ICC 均大于 0.90。在两个位置测量 UCL 厚度具有非常好到极好的可靠性和高精度。使用此方案,两名评估者可以在两个位置获得一致的 UCL 测量结果。这一发现对两名经验丰富的从业者对同一个体的浅表组织病理学进行临床评估具有重要意义。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b408/10252878/82cc179236a4/peerj-11-15418-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验