Suppr超能文献

超声造影对肝移植术后肝动脉闭塞的诊断性能:系统评价和荟萃分析。

Diagnostic performance of contrast-enhanced ultrasound in diagnosing hepatic artery occlusion after liver transplantation: A systematic review and meta-analysis.

机构信息

Department of Internal Medicine, Texas Tech University Health Sciences Center, Lubbock, Texas, USA.

Department of Internal Medicine, University of Nebraska Medical Center, Omaha, Nebraska, USA.

出版信息

Clin Transplant. 2023 Nov;37(11):e15070. doi: 10.1111/ctr.15070. Epub 2023 Jul 3.

Abstract

INTRODUCTION

Hepatic artery occlusion (HAO) is a significant complication post-liver transplantation. Doppler ultrasound (DUS) has been widely used as an initial screening test for detecting HAO; however, its performance is often not sufficient. Although other diagnostic tests such as computed tomography angiography (CTA), magnetic resonance angiography (MRA), and angiogram are more accurate, they are invasive and have several limitations. Contrast-enhanced ultrasound (CEUS) is an emerging tool for detecting HAO; however, the results from previous studies were limited due to a small number of patients. Therefore, we aimed to evaluate its performance by performing a meta-analysis.

METHOD

We performed a systemic review and meta-analysis of studies evaluating the performance of CEUS for the detection of HAO in an adult population. A literature search of EMBASE, Scopus, CINAHL, and Medline was conducted through March 2022. Pooled sensitivity, specificity, log diagnostic odd ratio (LDOR), and area under summary receiver operating curve (AUC) were calculated. Publication bias was assessed by Deeks' funnel plot.

RESULT

Eight studies were included, with 434 CEUS performed. Using a combination of CTA, MRA, angiography, clinical follow-up, and surgery as the gold standard, the sensitivity, specificity, and LDOR of CEUS for detection of HAO were .969 (.938, .996), .991 (.981, 1.001), and 5.732 (4.539, 6.926), respectively. AUC was .959. The heterogeneity between studies appeared universally low, and no significant publication bias was found (p = .44).

CONCLUSION

CEUS appeared to have an excellent performance for the detection of HAO and could be considered as an alternative when DUS is non-diagnostic or when CTA, MRA, and angiogram are not feasible.

摘要

简介

肝动脉闭塞(HAO)是肝移植术后的一种严重并发症。多普勒超声(DUS)已广泛用于检测 HAO 的初始筛查试验;然而,其性能往往不够。虽然其他诊断测试,如计算机断层血管造影(CTA)、磁共振血管造影(MRA)和血管造影,更准确,但它们具有侵入性且存在多种局限性。对比增强超声(CEUS)是一种新兴的检测 HAO 的工具;然而,由于患者数量较少,以前的研究结果有限。因此,我们旨在通过进行荟萃分析来评估其性能。

方法

我们对评估成人人群中 CEUS 检测 HAO 的表现的研究进行了系统回顾和荟萃分析。通过 2022 年 3 月对 EMBASE、Scopus、CINAHL 和 Medline 进行文献检索。计算了汇总敏感性、特异性、对数诊断比值比(LDOR)和汇总受试者工作特征曲线下面积(AUC)。通过 Deeks 漏斗图评估发表偏倚。

结果

共纳入 8 项研究,共进行了 434 次 CEUS。使用 CTA、MRA、血管造影、临床随访和手术的组合作为金标准,CEUS 检测 HAO 的敏感性、特异性和 LDOR 分别为.969(.938,.996)、.991(.981,1.001)和 5.732(4.539,6.926)。AUC 为.959。研究之间的异质性普遍较低,未发现显著的发表偏倚(p=0.44)。

结论

CEUS 似乎在检测 HAO 方面具有出色的性能,当 DUS 无法诊断或 CTA、MRA 和血管造影不可行时,可以考虑作为替代方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验