Abstract

OBJECTIVE

Endomyocardial biopsy is the gold standard method for the diagnosis of cardiac allograft rejection. However, it causes damage to the heart. In this study, we developed a noninvasive method for quantification of granzyme B (GzB) by targeted ultrasound imaging, which detects and provides quantitative information for specific molecules, for acute rejection assessment in a murine cardiac transplantation model.

METHODS

Microbubbles bearing anti-GzB antibodies (MB) or isotype antibodies (MBcon) were prepared. Hearts were transplanted from C57BL/6J (allogeneic) or C3H (syngeneic) donors to C3H recipients. Target ultrasound imaging was performed on Days 2 and 5 post-transplantations. A pathologic assessment was performed. The expression of granzyme B and IL-6 in the heart was detected by Western blotting.

RESULTS

After MB injection, we observed and collected data at 3 and 6 min before and after the flash pulse. Quantitative analysis revealed that the reduction in peak intensity was significantly higher in the allogeneic MB group than in the allogeneic MB group and the isogeneic MB group at PODs 2 and 5. In the allogeneic groups, granzyme B and IL-6 expression levels were higher than those in the isogeneic group. In addition, more CD8 T cells and neutrophils were observed in the allogeneic groups.

CONCLUSION

Ultrasound molecular imaging of granzyme B can be used as a noninvasive method for acute rejection detection after cardiac transplantation.

摘要

目的

心肌内膜活检是诊断心脏移植物排斥反应的金标准方法。然而,它会对心脏造成损伤。在这项研究中,我们开发了一种通过靶向超声成像定量检测颗粒酶 B (GzB) 的非侵入性方法,该方法可检测和提供特定分子的定量信息,用于评估小鼠心脏移植模型中的急性排斥反应。

方法

制备携带抗 GzB 抗体(MB)或同种型抗体(MBcon)的微泡。将 C57BL/6J(同种异体)或 C3H(同基因)供体的心脏移植到 C3H 受体中。在移植后第 2 天和第 5 天进行靶向超声成像。进行病理评估。通过 Western blot 检测心脏中颗粒酶 B 和 IL-6 的表达。

结果

注射 MB 后,我们在闪光脉冲前后 3 分钟和 6 分钟观察并收集数据。定量分析显示,在 POD2 和 POD5 时,同种异体 MB 组的峰值强度降低幅度明显高于同种异体 MB 组和同基因 MB 组。在同种异体组中,颗粒酶 B 和 IL-6 的表达水平高于同基因组。此外,在同种异体组中观察到更多的 CD8 T 细胞和中性粒细胞。

结论

超声分子成像的颗粒酶 B 可作为心脏移植后急性排斥反应的一种非侵入性检测方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba39/10331296/817338f1f5e0/fimmu-14-1164183-g001.jpg

相似文献

1
Noninvasive quantification of granzyme B in cardiac allograft rejection using targeted ultrasound imaging.
Front Immunol. 2023 Jun 26;14:1164183. doi: 10.3389/fimmu.2023.1164183. eCollection 2023.
2
Analysis of effector mechanisms in murine cardiac allograft rejection.
Transpl Immunol. 1996 Mar;4(1):46-8. doi: 10.1016/s0966-3274(96)80033-5.
4
Apoptosis is involved in acute cardiac allograft rejection in rats.
Ann Thorac Surg. 1998 Jun;65(6):1604-9. doi: 10.1016/s0003-4975(98)00240-9.
6
Granzyme B-responsive fluorescent probe for non-invasive early diagnosis of transplant rejection.
Biosens Bioelectron. 2023 Jul 15;232:115303. doi: 10.1016/j.bios.2023.115303. Epub 2023 Apr 11.
8
Apoptosis and allograft rejection in the absence of CD8+ T cells.
Transplantation. 2001 Jun 27;71(12):1827-34. doi: 10.1097/00007890-200106270-00020.

引用本文的文献

1
Ultrasound molecular imaging of M2 macrophages for early detection of chronic rejection in heart transplantation.
J Nanobiotechnology. 2025 Aug 22;23(1):581. doi: 10.1186/s12951-025-03672-9.
3
Prediction of Acute Cardiac Rejection Based on Gene Expression Profiles.
J Pers Med. 2024 Apr 12;14(4):410. doi: 10.3390/jpm14040410.

本文引用的文献

1
Granzyme B-responsive fluorescent probe for non-invasive early diagnosis of transplant rejection.
Biosens Bioelectron. 2023 Jul 15;232:115303. doi: 10.1016/j.bios.2023.115303. Epub 2023 Apr 11.
2
Noninvasive Early Diagnosis of Allograft Rejection by a Granzyme B Protease Responsive NIR-II Bioimaging Nanosensor.
Angew Chem Int Ed Engl. 2023 Jun 5;62(23):e202301696. doi: 10.1002/anie.202301696. Epub 2023 May 3.
3
Nanomaterials as Ultrasound Theragnostic Tools for Heart Disease Treatment/Diagnosis.
Int J Mol Sci. 2022 Jan 31;23(3):1683. doi: 10.3390/ijms23031683.
4
Safety of Image-Guided Treatment of the Liver with Ultrasound and Microbubbles in an in Vivo Porcine Model.
Ultrasound Med Biol. 2021 Nov;47(11):3211-3220. doi: 10.1016/j.ultrasmedbio.2021.07.003. Epub 2021 Aug 4.
5
Current status of targeted microbubbles in diagnostic molecular imaging of pancreatic cancer.
Bioeng Transl Med. 2020 Sep 7;6(1):e10183. doi: 10.1002/btm2.10183. eCollection 2021 Jan.
6
Hidden Granzyme B-Mediated Injury in Chronic Active Antibody-Mediated Rejection.
Exp Clin Transplant. 2020 Dec;18(7):778-784. doi: 10.6002/ect.2020.0225.
7
Three Decades of Ultrasound Contrast Agents: A Review of the Past, Present and Future Improvements.
Ultrasound Med Biol. 2020 Apr;46(4):892-908. doi: 10.1016/j.ultrasmedbio.2019.12.008. Epub 2020 Jan 13.
8
Non-invasive early detection of acute transplant rejection via nanosensors of granzyme B activity.
Nat Biomed Eng. 2019 Apr;3(4):281-291. doi: 10.1038/s41551-019-0358-7. Epub 2019 Feb 18.
9
Prediction of renal allograft chronic rejection using a model based on contrast-enhanced ultrasonography.
Microcirculation. 2019 Aug;26(6):e12544. doi: 10.1111/micc.12544. Epub 2019 Apr 14.
10
Ultrasound-guided Microbubble in the Treatment of Cancer: A Mini Narrative Review.
Cureus. 2018 Sep 4;10(9):e3256. doi: 10.7759/cureus.3256.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验