Abstract

Enhanced computed tomography (CT) is unsuitable for patients with reduced renal function and/or allergy for contrast medium (CM). CT image registration into an electroanatomic system (EAMS) is essential to perform pulmonary vein isolation (PVI) safely and smoothly in patients with atrial fibrillation (AF). To create three-dimensional pulmonary vein-left atrium (3D PV-LA) images from non-enhanced CT images to register them into EAMS for AF ablation. Using a non-enhanced ECG-gated image, 3D PV-LA images were generated by our developed techniques with an EnSite image analyzing tool for patients unfit for CM use (n = 100). Segmentation between tissues was performed as follows: tissues distal from or close to PV-LA were segmented in transverse slices to clearly show the whole LA. Tissues bordering PV-LA, including the pulmonary artery, left ventricle, and right atrium, were segmented manually with great care. Practical ablation parameters were compared with those obtained from enhanced CT (n = 100). 3D PV-LA image reconstruction from non-enhanced CT imaging required a longer time than that from enhanced CT (42 ± 6 vs 14 ± 3 min). All 100 PV-LA non-enhanced CT images were successfully reconstructed and registered into the EAM system without the need for re-segmentation. Practical ablation parameters, including procedural time and AF recurrence rate, did not differ between imaging methods. This study provides clinically useful information on a detailed methodology for 3D PV-LA image reconstruction using non-enhanced CT. Non-enhanced CT 3D PV-LA images were successfully registered into the EAM system and useful for patients unsuitable for CM use.

摘要

增强计算机断层扫描(CT)不适合肾功能降低和/或对对比剂(CM)过敏的患者。CT 图像注册到电解剖系统(EAMS)对于在患有心房颤动(AF)的患者中安全平稳地进行肺静脉隔离(PVI)至关重要。为了从非增强 CT 图像创建三维肺静脉-左心房(3D PV-LA)图像,以便将其注册到 EAMS 中用于 AF 消融。使用非增强心电图门控图像,我们使用开发的技术和 EnSite 图像分析工具为不适合 CM 使用的患者(n=100)生成 3D PV-LA 图像。组织之间的分割如下进行:远离或靠近 PV-LA 的组织在横切面上进行分割,以清晰显示整个 LA。与 PV-LA 相邻的组织,包括肺动脉、左心室和右心房,小心地手动进行分割。比较了实用消融参数与增强 CT 获得的参数(n=100)。从非增强 CT 成像重建 3D PV-LA 图像所需的时间长于增强 CT(42±6 与 14±3 分钟)。无需重新分割,成功重建了 100 个非增强 CT 图像并将其注册到 EAM 系统中。实用消融参数,包括手术时间和 AF 复发率,在两种成像方法之间没有差异。本研究为使用非增强 CT 进行 3D PV-LA 图像重建的详细方法提供了临床有用的信息。非增强 CT 3D PV-LA 图像成功注册到 EAM 系统中,适用于不适合 CM 使用的患者。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验