Tang Camelia Qian Ying, Chuah Khoon Leong, Teoh Lam Chuan
Department of Hand and Reconstructive Microsurgery, Tan Tock Seng Hospital, Singapore.
Department of Pathology, Tan Tock Seng Hospital, Singapore.
J Hand Microsurg. 2022 Jun 28;15(4):318-321. doi: 10.1055/s-0042-1748762. eCollection 2023 Sep.
Adverse reaction to metal debris (ARMD) consists of a spectrum of changes ranging from pure metallosis to aseptic lymphocytic vasculitis-associated lesion and granulomatous inflammation. Currently described ARMD cases are mainly limited to arthroplasty, typically total hip and knee arthroplasties in the lower limb and total wrist arthroplasty in the upper limb. Hypersensitivity to a metallic implant in fracture fixation is rare, and a severe form of metallosis has not been reported so far. In this paper, we present a case of ARMD occurring 10 years after the use of titanium implants for fracture fixation in the hand. Intra-operative findings, histopathological results, and a literature review on ARMD are also described.
金属碎屑不良反应(ARMD)包括一系列变化,从单纯的金属沉着症到无菌性淋巴细胞性血管炎相关病变和肉芽肿性炎症。目前报道的ARMD病例主要局限于关节置换术,典型的是下肢的全髋关节和膝关节置换术以及上肢的全腕关节置换术。骨折固定中对金属植入物的超敏反应很少见,迄今为止尚未报道过严重形式的金属沉着症。在本文中,我们报告了1例手部使用钛植入物进行骨折固定10年后发生ARMD的病例。还描述了术中发现、组织病理学结果以及关于ARMD的文献综述。