3D 打印乳前牙预成氧化锆全冠修复的最佳牙合面高度和颊舌径。

Optimal post height and diameter in preformed zirconia crown restoration on 3D-printed primary incisors.

机构信息

Department of Pediatric Dentistry, School of Dentistry, Kyungpook National University, 41940 Daegu, Republic of Korea.

出版信息

J Clin Pediatr Dent. 2023 Sep;47(5):57-64. doi: 10.22514/jocpd.2023.053. Epub 2023 Sep 3.

Abstract

In this study, fracture resistance was evaluated according to the post-diameter and -length in zirconia crown restorations on three-dimensional printed primary incisors undergone pulpectomy. One hundred-and-sixty primary incisor abutments were used which were artificially fabricated through 3D-printing. Each group was divided into two subgroups based on the zirconia post-diameter (1.5 mm and 2.0 mm) employed for post setting after pulpectomy. Furthermore, each group was divided into four subgroups based on the zirconia post-height (3.0, 4.0, 5.0 and 6.0 mm). Zirconia post setting was made by applying flowable resin after filling the pulp cavity with calcium hydroxide up to 3.0 mm below cemento-enamel junction (CEJ). Finally, a preformed zirconia crown of size #1 was cemented to the abutment through resin cement. A compressive load was applied to the middle palatal surface of incisors restored with zirconia crowns by using a universal testing machine at 145° angle which is the normal interincisal angle of children. The root fracture specimens were excluded and the samples fractured within crown and core parts were included in the final fracture resistance analysis. The group with 1.5-mm post-diameter and 5.0-mm post-height had the highest fracture resistance strength (130.63 ± 55.75 N) under masticatory pressure condition. Fracture resistance was statistically greater in 5.0-mm than in 4.0-mm and 3.0-mm post-height groups for 1.5-mm post-diameter subgroup. Moreover, 5.0-mm post-height subgroup had a statistically greater fracture resistance than that of 3.0-mm post-height subgroup for 2.0-mm post-diameter group. The 2.0-mm post-diameter subgroup had a statistically greater fracture resistance than that of 1.5-mm post-diameter subgroup for 3.0-mm and 4.0-mm post-heights. If zirconia post incorporation is required for deciduous incisor restoration, a post-length equal to facial CEJ level is recommended for gaining additional retention against masticatory pressure.

摘要

本研究评估了根管治疗后的乳前牙经 3D 打印后,用不同直径和长度的氧化锆桩核修复的抗折性能。使用 160 个乳前牙作为基牙,通过 3D 打印人工制作。每组根据根管治疗后使用的氧化锆桩直径(1.5mm 和 2.0mm)分为两组。此外,每组根据氧化锆桩高度(3.0mm、4.0mm、5.0mm 和 6.0mm)分为四组。根管治疗后,在牙本质腔中填充氢氧化钙至釉牙骨质界(CEJ)下 3.0mm 处,然后用流动性树脂固定氧化锆桩。最后,通过树脂水泥将尺寸为 #1 的预成型氧化锆冠固定在基牙上。通过万能试验机以 145°的角度向修复后的氧化锆冠的腭中面施加压缩载荷,这是儿童正常的切牙间角度。排除根折标本,将冠核内折断的样本纳入最终的抗折强度分析。在咀嚼压力条件下,直径 1.5mm、高度 5.0mm 的氧化锆桩组具有最高的抗折强度(130.63±55.75N)。对于直径 1.5mm 的桩,高度 5.0mm 的桩组的抗折强度显著大于高度 4.0mm 和 3.0mm 的桩组。此外,对于直径 2.0mm 的桩,高度 5.0mm 的桩组的抗折强度显著大于高度 3.0mm 的桩组。对于高度 3.0mm 和 4.0mm 的桩,直径 2.0mm 的桩组的抗折强度显著大于直径 1.5mm 的桩组。如果需要对乳前牙进行氧化锆桩核修复,建议桩长与牙冠的切缘平齐,以获得对抗咀嚼压力的额外固位力。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验