在体外膜肺氧合(VA-ECMO)期间预防急性肢体缺血——与下肢灌注相关的物理参数的计算机模拟分析

Preventing Acute Limb Ischemia during VA-ECMO-In Silico Analysis of Physical Parameters Associated with Lower Limb Perfusion.

作者信息

Brockaert Tifanie, Ferreira Inês, Laplante Anne, Fogel Paul, Grimbert David, Mordant Pierre

机构信息

Université de Technologie de Compiègne, 60200 Compiègne, France.

Iperf, 1 Avenue de Champfleury, 69410 Champagne-au-Mont-d'Or, France.

出版信息

J Clin Med. 2023 Sep 19;12(18):6049. doi: 10.3390/jcm12186049.

Abstract

BACKGROUND

Peripheral femoro-femoral veno-arterial extracorporeal membrane oxygenation is increasingly used in refractory cardiogenic shock. However, the obstruction of the femoral artery by the return cannula could lead to acute limb ischemia, a frequently encountered situation that is inconstantly prevented by the adjunction of a distal perfusion cannula (DPC). The aim of this study was to investigate the influence of three physical parameters on the perfusion of the cannulated lower limb.

METHODS

Using patient-specific arterial models and computational fluid dynamic simulations, we studied four diameters of arterial cannula, three diameters of DPC, and two percentages of arterial section limitation.

RESULTS

We found that adequate perfusion of the cannulated limb was achieved in only two out of the twenty-one configurations tested, specifically, when the arterial cannula had a diameter of 17 Fr, was considered to limit the section of the artery by 90%, and was associated with an 8 Fr or a 10 Fr DPC. Multivariable analysis revealed that the perfusion of the cannulated lower limb was correlated with the diameter of the DPC, but also with the diameter of the arterial cannula and the percentage of arterial section limitation.

CONCLUSIONS

In most of the cases simulated here, the current system combining unsized arterial cannula and non-specific DPC was not sufficient to provide adequate perfusion of the cannulated lower limb, urging the need for innovative strategies to efficiently prevent acute limb ischemia during peripheral femoro-femoral veno-arterial extracorporeal membrane oxygenation.

摘要

背景

外周股-股静脉-动脉体外膜肺氧合越来越多地用于难治性心源性休克。然而,回流插管对股动脉的阻塞可能导致急性肢体缺血,这是一种常见情况,使用远端灌注插管(DPC)并不能始终预防这种情况。本研究的目的是探讨三个物理参数对插管下肢灌注的影响。

方法

使用患者特异性动脉模型和计算流体动力学模拟,我们研究了四种动脉插管直径、三种DPC直径和两种动脉截面受限百分比。

结果

我们发现在测试的21种配置中,只有两种实现了插管肢体的充分灌注,具体而言,当动脉插管直径为17 Fr,动脉截面被认为受限90%,并且与8 Fr或10 Fr的DPC相关联时。多变量分析显示,插管下肢的灌注与DPC直径相关,但也与动脉插管直径和动脉截面受限百分比相关。

结论

在本研究模拟的大多数情况下,当前将未确定尺寸的动脉插管和非特异性DPC相结合的系统不足以提供插管下肢的充分灌注,这促使需要创新策略来有效预防外周股-股静脉-动脉体外膜肺氧合期间的急性肢体缺血。