Losurdo Giuseppe, De Bellis Margherita, Rima Raffaella, Palmisano Chiara Maria, Dell'Aquila Paola, Iannone Andrea, Ierardi Enzo, Di Leo Alfredo, Principi Mariabeatrice
Section of Gastroenterology, Department of Precision and Regenerative Medicine and Ionian Area, University of Bari, 70124 Bari, Italy.
Internal Medicine Unit "C. Frugoni", Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", Piazza Giulio Cesare 11, 70124 Bari, Italy.
J Clin Med. 2023 Dec 15;12(24):7714. doi: 10.3390/jcm12247714.
The diagnosis of Crohn's Disease (CD) is based on a combination of clinical symptoms, laboratory tests, endoscopy, and imaging data. In Small Intestine Contrast Ultrasonography (SICUS), the ingestion of a macrogol solution as an oral contrast medium may optimize image quality. We performed a meta-analysis to evaluate the diagnostic performance of SICUS for CD. A literature search was performed in August 2023. We selected only studies where SICUS was compared to a technique that allows the assessment of the whole gastrointestinal tract, such as an MRE, a CT scan, or a surgical evaluation. We estimated pooled weighted sensitivity, specificity, and likelihood ratio for positive and negative tests (PLR/NLR) of SICUS. Summary receiver operating characteristic curves (SROC) were drawn, and pooled areas under the curve (AUC) were calculated. Five studies with 325 CD patients were included. SICUS showed a pooled sensitivity for the diagnosis of 95% (95% confidence interval CI 89-99%), a specificity = 77% (95% CI 60-90%), and the AUC was 0.94. SICUS demonstrated a pooled sensitivity for strictures of 78% (95% CI 63-88%) and a specificity = 96% (95% CI 85-99%), with AUC = 0.93. For abscesses, SICUS demonstrated a pooled sensitivity of 100% (95% CI 59-100%) and a specificity of 90% (95% CI 74-98%). Fistulae were detected with a pooled sensitivity of 77% (95% CI 46-95%) and a specificity of 92% (95% CI 75-99%). SICUS demonstrated excellent diagnostic performance compared to the gold standard despite some clinical scenarios (stenosis/fistulae) showing suboptimal diagnostic effectiveness.
克罗恩病(CD)的诊断基于临床症状、实验室检查、内镜检查和影像学数据的综合判断。在小肠造影超声检查(SICUS)中,摄入聚乙二醇溶液作为口服造影剂可能会优化图像质量。我们进行了一项荟萃分析,以评估SICUS对CD的诊断性能。于2023年8月进行了文献检索。我们仅选择了将SICUS与能够评估整个胃肠道的技术(如磁共振小肠造影(MRE)、CT扫描或手术评估)进行比较的研究。我们估计了SICUS的合并加权敏感性、特异性以及阳性和阴性试验的似然比(PLR/NLR)。绘制了汇总的受试者工作特征曲线(SROC),并计算了曲线下的合并面积(AUC)。纳入了五项研究,共325例CD患者。SICUS对诊断的合并敏感性为95%(95%置信区间CI 89 - 99%),特异性为77%(95%CI 60 - 90%),AUC为0.94。SICUS对狭窄的合并敏感性为78%(95%CI 63 - 88%),特异性为96%(95%CI 85 - 99%),AUC = 0.93。对于脓肿,SICUS的合并敏感性为100%(95%CI 59 - 100%),特异性为90%(95%CI 74 - 98%)。检测瘘管的合并敏感性为77%(95%CI 46 - 95%),特异性为92%(95%CI 75 - 99%)。尽管在某些临床情况(狭窄/瘘管)下诊断效果欠佳,但与金标准相比,SICUS仍表现出出色的诊断性能。