Sonntag N, Borchardt S, Heuwieser W, Sutter F
Clinic for Animal Reproduction, Faculty of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany.
JDS Commun. 2023 Oct 6;5(1):72-76. doi: 10.3168/jdsc.2023-0393. eCollection 2024 Jan.
The objective of this study was to correlate movement assessed by a pyroelectric infrared sensor system in preweaning dairy calves with lying and standing time assessed by a 3D accelerometer considering the temperature-humidity index (THI). A total of 35 dairy calves (1-7 d of age) were enrolled in the study and 20 calves were included in the final analyses. The lying and standing time of the calves was monitored with a 3D accelerometer (Hobo Pendant G Data Logger, Onset Computer Corporation, USA), which was used as the gold standard reference. The infrared sensor monitoring system (IMS; Calf Monitoring System, Futuro Farming GmbH, Germany) was fixed to the fence of the calf hutch within the calf's reach. Temperature-humidity was monitored with 2 validated THI sensors inside and on outside of each calf hutch. Additionally, one THI sensor was located near the calf hutches. The observation period lasted 14 consecutive days. The average standing time assessed by the 3D accelerometer was 13.4 ± 12.7 (mean ± standard deviation) min/h and the average lying time was 46.6 (±12.7) min/h. The median (25th percentile; 75th percentile) number of movements measured by the IMS was 360 (60; 919) movements per hour. Number of movements per hour measured by the IMS was compared with data obtained with a validated 3D accelerometer. The Pearson correlation coefficient between both standing and lying time and the number of movements was r = 0.85 and r = -0.85, respectively. The Pearson correlation coefficients were only slightly influenced by THI (low THI [<68]: r = 0.86; medium THI [68-72]: r = 0.85; high THI [>72]: r = 0.81). Our data show that the number of movements of dairy calves measured by IMS were highly correlated with the chosen gold standard reference method. High THI slightly affects the measurement accuracy of IMS.
本研究的目的是将热释电红外传感器系统评估的断奶前奶牛犊牛的活动与考虑温度湿度指数(THI)的三维加速度计评估的躺卧和站立时间进行关联。共有35头奶牛犊牛(1至7日龄)参与本研究,最终分析纳入了20头犊牛。使用三维加速度计(美国Onset Computer Corporation公司的Hobo Pendant G数据记录器)监测犊牛的躺卧和站立时间,该加速度计用作金标准参考。红外传感器监测系统(IMS;德国Futuro Farming GmbH公司的犊牛监测系统)固定在犊牛栏舍围栏上犊牛能够触及的位置。在每个犊牛栏舍内部和外部使用2个经验证的THI传感器监测温度湿度。此外,在犊牛栏舍附近放置了一个THI传感器。观察期持续14天。三维加速度计评估的平均站立时间为13.4±12.7(平均值±标准差)分钟/小时,平均躺卧时间为46.6(±12.7)分钟/小时。IMS测量的每小时活动中位数(第25百分位数;第75百分位数)为360(60;919)次。将IMS测量的每小时活动次数与经验证的三维加速度计获得的数据进行比较。站立时间和躺卧时间与活动次数之间的Pearson相关系数分别为r = 0.85和r = −0.85。Pearson相关系数仅受THI的轻微影响(低THI [<68]:r = 0.86;中等THI [68 - 72]:r = 0.85;高THI [>72]:r = 0.81)。我们的数据表明,IMS测量的奶牛犊牛活动次数与所选的金标准参考方法高度相关。高THI对IMS的测量准确性有轻微影响。