18F-氟代脱氧葡萄糖正电子发射断层显像/计算机断层扫描(18F-FDG PET/CT)在疑似心脏植入式电子设备感染患者管理中的作用

The Role of the F-FDG PET/CT in the Management of Patients Suspected of Cardiac Implantable Electronic Devices' Infection.

作者信息

Pisani Antonio Rosario, Rubini Dino, Altini Corinna, Ruta Rossella, Gazzilli Maria, Sardaro Angela, Iuele Francesca, Maggialetti Nicola, Rubini Giuseppe

机构信息

Interdisciplinary Department of Medicine, Section of Nuclear Medicine, University of Bari "Aldo Moro", Policlinic of Bari, Piazza Giulio Cesare 11, 70124 Bari, Italy.

Radiotherapy, Precision Medicine Department, University of Campania "Luigi Vanvitelli", 80138 Naples, Italy.

出版信息

J Pers Med. 2024 Jan 4;14(1):65. doi: 10.3390/jpm14010065.

Abstract

Infection of Cardiac Implantable Electronic Devices (CIEDI) is a real public health problem. The main aim of this study was to determine the diagnostic performance of F-FDG PET/CT in the diagnosis of CIEDI. A total of 48 patients, who performed F-FDG PET/CT for the clinical suspicion of CIEDI were retrospectively analyzed; all patients were provided with a model with procedural recommendations before the exam. Sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy (DA) of F-FDG PET/CT were calculated; the reproducibility of qualitative analysis was assessed with Cohen's κ test. The semi-quantitative parameters (SUVmax, SQR and TBR) were evaluated in CIEDI+ and CIEDI- patients using the Student' -test; ROC curves were elaborated to detect cut-off values. The trend of image quality with regards to procedural recommendation adherence was evaluated. Se, Sp, PPV, NPV and DA were respectively 96.2%, 81.8%, 86.2%, 94.7% and 89.6%. The reproducibility of qualitative analysis was excellent (K = 0.89). Semiquantitative parameters resulted statistically different in CIEDI+ and CIEDI- patients. Cut-off values were SUV = 2.625, SQR = 3.766 and TBR = 1.29. Trend curves showed increasing image quality due to adherence to procedural recommendations. F-FDG-PET/CT is a valid tool in the management of patients suspected of CIEDI and adherence to procedural recommendations improves its image quality.

摘要

心脏植入式电子设备(CIEDI)感染是一个切实存在的公共卫生问题。本研究的主要目的是确定F-FDG PET/CT在CIEDI诊断中的诊断性能。对48例因临床怀疑CIEDI而进行F-FDG PET/CT检查的患者进行回顾性分析;所有患者在检查前均获得了带有程序建议的模型。计算F-FDG PET/CT的敏感性(Se)、特异性(Sp)、阳性预测值(PPV)、阴性预测值(NPV)和诊断准确性(DA);采用Cohen's κ检验评估定性分析的可重复性。使用Student'-检验在CIEDI+和CIEDI-患者中评估半定量参数(SUVmax、SQR和TBR);绘制ROC曲线以检测临界值。评估了图像质量随程序建议依从性的变化趋势。Se、Sp、PPV、NPV和DA分别为96.2%、81.8%、86.2%、94.7%和89.6%。定性分析的可重复性极佳(K = 0.89)。半定量参数在CIEDI+和CIEDI-患者中具有统计学差异。临界值为SUV = 2.625、SQR = 3.766和TBR = 1.29。趋势曲线显示,由于遵守程序建议,图像质量有所提高。F-FDG-PET/CT是管理疑似CIEDI患者的有效工具,遵守程序建议可提高其图像质量。