Department of Prosthodontics and Crown and Bridges, Institute of Dental Studies and Technologies, Affiliated with Chaudhary Charan Singh University, Meerut, Uttar Pradesh, India.
J Indian Prosthodont Soc. 2024 Jan 1;24(1):69-75. doi: 10.4103/jips.jips_201_23. Epub 2024 Jan 24.
The primary objective of this research was to assess and compare the impact of customized zirconia (Zr) and titanium (Ti) abutments, placed on early loaded dental implants, on both hard tissue (as measured crestal bone level) and soft tissue (as assessed by sulcular bleeding index [SBI], probing depth [PD], and Pink Esthetic Score [PES]), through clinical and radiographic evaluation.
This research involved a sample of 15 patients who had partially dentulous mandibular arch. Within this group, a total of 30 implants were surgically placed. Specifically, each patient received two implants in the posterior region of the mandible, and the bone density in this area was classified as D2 type. In each patient, one implant was loaded with Zr abutment and the other was loaded with Ti abutment. The bone quality in the area of implant placement was Type D2. Two groups were created for this research. Each group consisted of 15 early loaded dental implants with customized Zr abutments and customized Ti abutments respectively.
Hard- and soft-tissue changes were evaluated in both the groups. Evaluation of crestal bone loss (CBL) with cone beam computed tomography and SBI, PD and PESs were evaluated by various indices at 2, 4, and 6 months postloading.
After obtaining the readings, data were subjected to statistical analysis and comparison of quantitative data was done, paired t-test was used.
The mean CBL in the Ti abutment is higher; the difference between the two groups was not statistically significant. SBI and PD for Zr were higher, but there was no statistically significant difference between the two groups. Zr had a higher PES than Ti abutment and the difference between the two groups was statistically significant. In the literature till date, the PES of Zr abutments were proven better for provisional restorations in implant prosthesis, but very few literatures support the same for the final implant restorations.
The study did not reveal a clear advantage of either Ti or Zr abutments over the other. Nevertheless, Zr abutments tended to produce a more favorable color response in the peri-implant mucosa and led to superior esthetic outcomes as measured by the PES.
本研究的主要目的是评估和比较定制氧化锆(Zr)和钛(Ti)基台对早期负载种植体的硬组织(如测量的牙槽骨水平)和软组织(如通过龈沟出血指数[SBI]、探诊深度[PD]和粉色美学评分[PES]评估)的影响。
本研究涉及 15 名下颌部分缺牙患者的样本。在该组中,总共植入了 30 个种植体。具体来说,每位患者的下颌后牙区植入了 2 个种植体,该区域的骨密度被归类为 D2 型。在每位患者中,一个种植体加载 Zr 基台,另一个加载 Ti 基台。种植体植入部位的骨质量为 D2 型。为这项研究创建了两个组。每个组分别由 15 个带有定制 Zr 基台和定制 Ti 基台的早期负载种植体组成。
在两组中评估了硬组织和软组织的变化。通过锥形束计算机断层扫描和 SBI、PD 和 PES 评估植入后 2、4 和 6 个月的牙槽骨丧失(CBL)。
获得读数后,对数据进行统计分析,并对定量数据进行比较,使用配对 t 检验。
Ti 基台的平均 CBL 较高;两组之间的差异无统计学意义。Zr 的 SBI 和 PD 较高,但两组之间无统计学差异。Zr 的 PES 高于 Ti 基台,两组之间的差异具有统计学意义。在迄今为止的文献中,Zr 基台的 PES 被证明更适合种植体义齿的临时修复,但很少有文献支持最终的种植体修复。
本研究并未显示 Ti 或 Zr 基台明显优于另一种基台。然而,Zr 基台在种植体周围黏膜中产生更有利的颜色反应,并且根据 PES 测量,结果更美观。