Lin Gengbing, Chen Mengwei, Guo Nan, Shi Xie
Gengbing Lin, Department of Stomatology, Fujian Provincial People's Hospital, Affiliated People's Hospital of Fujian University of Traditional Chinese Medicine, Fuzhou 350004, Fujian, China.
Mengwei Chen, Department of Orthodontics, Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University & Institute of Stomatology, Fujian Medical University, Fuzhou 350004, Fujian, China.
Pak J Med Sci. 2024 Jan-Feb;40(3Part-II):455-460. doi: 10.12669/pjms.40.3.7759.
To investigate the effect of micro-implant anchorage combined with a clear aligner on the efficiency of mandibular molar distalization and the protection of anterior teeth anchorage, provide reference for clinical scheme design.
This is a prospective study. Seventeen patients who were treated in the Orthodontics Department of the Hospital of Stomatology affiliated to Fujian Medical University from 2019 to 2021 and used Invisalign clear aligners to move mandibular molars distally were included and divided into two groups according to anchorage types: Group-A and Group-B. Group-A (ten cases) were treated without micro-implant anchorage, while Group-B (seven cases) were treated with micro-implant anchorage nails for enhanced anchorage. The effect of micro-implant anchorage on crown and root distal movement of mandibular molars and the difference in three-dimensional movement between mandibular molars and mandibular central incisors were analyzed.
The crown distalization efficiency of mandibular first and second molars in Group-B was 68.66% and 71.02%, respectively, which were higher than those in Group-A(p<0.05). The mandibular central incisors in Group-A showed labial displacement and a small amount of elongation, while those in Group-B showed less anchorage loss(p<0.05). In Group-A, the crown was tilted in the distal direction and moved in the buccal direction during mandibular molar distalization(p<0.05). While in Group-B, the crown was tilted in the distal directio (p<0.05) and the mandibular second molar was depressed(p<0.05).
In the process of mandibular molar distalization assisted by micro-implant anchorage combined with a clear aligner, better protects the anchorage of the mandibular central incisor and improves the efficiency of the molar crown distalization.
探讨微型种植体支抗联合隐形矫治器在下颌磨牙远移效率及保护前牙支抗方面的作用,为临床方案设计提供参考。
本研究为前瞻性研究。纳入2019年至2021年在福建医科大学附属口腔医院正畸科就诊、使用隐适美隐形矫治器远移下颌磨牙的17例患者,根据支抗类型分为两组:A组和B组。A组(10例)未使用微型种植体支抗进行治疗,B组(7例)使用微型种植体支抗钉增强支抗。分析微型种植体支抗对下颌磨牙冠根远移的影响以及下颌磨牙与下颌中切牙三维移动的差异。
B组下颌第一、二磨牙的冠远移效率分别为68.66%和71.02%,高于A组(p<0.05)。A组下颌中切牙出现唇向移位及少量伸长,而B组支抗丧失较少(p<0.05)。A组在下颌磨牙远移过程中冠向远中倾斜并向颊侧移动(p<0.05)。而B组冠向远中倾斜(p<0.05)且下颌第二磨牙有压低(p<0.05)。
微型种植体支抗联合隐形矫治器辅助下颌磨牙远移过程中,能更好地保护下颌中切牙的支抗并提高磨牙冠远移效率。