Departamento de Química, Universidade Federal do Paraná (UFPR), Centro Politécnico, C. P. 19032, Curitiba, PR, Brazil, CEP 81531-980.
Anal Methods. 2024 Mar 28;16(13):1880-1886. doi: 10.1039/d3ay02291a.
The study of ibuprofen (IBU) preconcentration was carried out making use of a homemade column for solid-phase extraction (SPE), using vermiculite (VT) or organo-vermiculites (OVTs) as sorbent phases. Aqueous samples (50.0 mL) percolated the column and IBU was sorbed onto the VT or OVT and then desorbed using acetonitrile. Employing this SPE system and OVT, calibration curves were generated for IBU, by spectrophotometric quantification using the α-naphthylamine method. values higher than 0.9950 and LOD between 12 and 18 μg L were observed, for real enrichment factors of 21 and 31, by using OVTs. The analytical protocol was applied to three water samples, which were spiked with IBU solutions to evaluate the precision and accuracy of the method. Recoveries between 77 and 110% at three different IBU concentrations and RSD lower than 18% were observed, even by using the spectrophotometric method. The protocol developed in this study demonstrated that the OVT was appropriate to work as a preconcentration phase for IBU determination in water samples.
采用自制的固相萃取柱(SPE),利用蛭石(VT)或有机蛭石(OVT)作为吸附相,对布洛芬(IBU)进行预浓缩研究。将 50.0mL 水样通过柱体,IBU 被 VT 或 OVT 吸附,然后用乙腈解吸。采用该 SPE 系统和 OVT,通过使用 α-萘胺法进行分光光度定量,为 IBU 生成了校准曲线。使用 OVT 观察到 值高于 0.9950 和 LOD 在 12 到 18 μg/L 之间,真实的富集因子为 21 和 31。该分析方案应用于三种水样,用 IBU 溶液进行了加标,以评估方法的精密度和准确度。在三个不同的 IBU 浓度下,回收率在 77%至 110%之间,RSD 低于 18%,即使使用分光光度法也是如此。本研究中开发的方案表明,OVT 适合作为水样品中 IBU 测定的预浓缩相。