Suppr超能文献

定量超声分析在可疑 MASLD 患者肝脂肪变中的操作者间可重复性:一项前瞻性研究。

Interoperator reproducibility of quantitative ultrasound analysis of hepatic steatosis in participants with suspected MASLD: A prospective study.

机构信息

Department of Ultrasound, Institute of Ultrasound in Medicine and Engineering, Zhongshan Hospital, Fudan University, Shanghai 200032, China; Shanghai Institute of Medical Imaging, Fudan University, Shanghai 200032, China; Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai 200032, China.

Department of Ultrasound, Institute of Ultrasound in Medicine and Engineering, Zhongshan Hospital, Fudan University, Shanghai 200032, China.

出版信息

Eur J Radiol. 2024 Jun;175:111427. doi: 10.1016/j.ejrad.2024.111427. Epub 2024 Mar 16.

Abstract

OBJECTIVES

To evaluate the reproducibility of tissue attenuation imaging (TAI) and tissue scatter distribution imaging (TSI) measurements in adults with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) between radiologists with varying experience.

MATERIALS AND METHODS

Participants with suspected MASLD were prospectively recruited. TAI and TSI were performed for each participant by two radiologists with different levels of experience. Interoperability reliability was assessed on the basis of Bland-Altman analysis and intraclass correlation coefficients (ICCs). The study determined and compared the diagnostic performance of TAI and TSI with clinical prediction models using proton magnetic resonance spectroscopy (H-MRS) as a reference.

RESULTS

A total of 180 participants (women, n = 56; men, n = 124, mean age, 46.98 ± 14.92 years; mean BMI, 25.81 ± 4.47) were enrolled from August 2022 to September 2022. Bland-Altman plots showed only slight deviation in the TAI and TSI results of the two radiologists; there was good interoperator reproducibility for TAI (ICC = 0.92) and TSI (ICC = 0.86). Senior and junior radiologists performed examinations labeled as TAI-1 and TSI-1, and TAI-2 and TSI-2, respectively. The areas under the curves (AUCs) of TAI-1, TAI-2, TSI-1, and TAI-2 for the detection of ≥5 % hepatic steatosis were 0.90, 0.96, 0.91 and 0.96, respectively. According to ROC analysis, the diagnostic performance of both radiologists for TAI and TSI was statistically similar and superior to that of the clinical prediction model.

CONCLUSIONS

TAI and TSI have good reproducibility between radiologists with different levels of experience. Meanwhile, both TAI and TSI demonstrated good diagnostic performance for hepatic steatosis (≥5%), surpassing that of clinical prediction models.

摘要

目的

评估在经验不同的放射科医师之间,对疑似代谢功能障碍相关性脂肪性肝病(MASLD)的成人进行组织衰减成像(TAI)和组织散射分布成像(TSI)测量的可重复性。

材料与方法

前瞻性招募疑似 MASLD 的参与者。由两名经验不同的放射科医师对每位参与者进行 TAI 和 TSI 检查。基于 Bland-Altman 分析和组内相关系数(ICC)评估可操作性可靠性。该研究使用质子磁共振波谱(H-MRS)作为参考,确定并比较了 TAI 和 TSI 与临床预测模型的诊断性能。

结果

本研究共纳入了 180 名参与者(女性 56 名,男性 124 名,平均年龄为 46.98±14.92 岁,平均 BMI 为 25.81±4.47),他们均于 2022 年 8 月至 2022 年 9 月入组。Bland-Altman 图显示两名放射科医师的 TAI 和 TSI 结果仅略有偏差;TAI(ICC=0.92)和 TSI(ICC=0.86)的操作者间可重复性良好。高级和初级放射科医师分别进行 TAI-1 和 TSI-1 以及 TAI-2 和 TSI-2 的检查。TAI-1、TAI-2、TSI-1 和 TSI-2 检测≥5%肝脂肪变性的曲线下面积(AUC)分别为 0.90、0.96、0.91 和 0.96。根据 ROC 分析,两名放射科医师的 TAI 和 TSI 的诊断性能在统计学上相似,均优于临床预测模型。

结论

经验不同的放射科医师之间 TAI 和 TSI 具有良好的可重复性。同时,TAI 和 TSI 对肝脂肪变性(≥5%)的诊断性能均良好,优于临床预测模型。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验