J Orthop Res. 2024 Sep;42(9):2072-2079. doi: 10.1002/jor.25848. Epub 2024 Apr 9.
Paraspinal muscle atrophy is gaining attention in spine surgery due to its link to back pain, spinal degeneration and worse postoperative outcomes. Electrical impedance myography (EIM) is a noninvasive diagnostic tool for muscle quality assessment, primarily utilized for patients with neuromuscular diseases. However, EIM's accuracy for paraspinal muscle assessment remains understudied. In this study, we investigated the correlation between EIM readings and MRI-derived muscle parameters, as well as the influence of dermal and subcutaneous parameters on these readings. We retrospectively analyzed patients with lumbar spinal degeneration who underwent paraspinal EIM assessment between May 2023 to July 2023. Paraspinal muscle fatty infiltration (FI) and functional cross-sectional area (fCSA), as well as the subcutaneous thickness were assessed on MRI scans. Skin ultrasound imaging was assessed for dermal thickness and the echogenicities of the dermal and subcutaneous layers. All measurements were performed on the bilaterally. The correlation between EIM readings were compared with ultrasound and MRI parameters using Spearman's correlation analyses. A total of 20 patients (65.0% female) with a median age of 69.5 years (IQR, 61.3-73.8) were analyzed. The fCSA and FI did not significantly correlate with the EIM readings, regardless of frequency. All EIM readings across frequencies correlated with subcutaneous thickness, echogenicity, or dermal thickness. With the current methodology, paraspinal EIM is not a valid alternative to MRI assessment of muscle quality, as it is strongly influenced by the dermal and subcutaneous layers. Further studies are required for refining the methodology and confirming our results.
由于与背痛、脊柱退化和术后结果不佳有关,脊柱外科中人们越来越关注脊柱旁肌肉萎缩。电阻抗肌描记法(EIM)是一种用于肌肉质量评估的非侵入性诊断工具,主要用于神经肌肉疾病患者。然而,EIM 用于评估脊柱旁肌肉的准确性仍有待研究。在这项研究中,我们研究了 EIM 读数与 MRI 衍生的肌肉参数之间的相关性,以及皮肤和皮下参数对这些读数的影响。我们回顾性分析了 2023 年 5 月至 2023 年 7 月间接受脊柱旁 EIM 评估的腰椎脊柱退变患者。在 MRI 扫描中评估脊柱旁肌肉脂肪浸润(FI)和功能横截面积(fCSA)以及皮下厚度。对皮肤超声成像进行评估,以测量真皮厚度以及真皮和皮下层的回声。所有测量均在双侧进行。使用 Spearman 相关分析比较 EIM 读数与超声和 MRI 参数之间的相关性。共分析了 20 名患者(65.0%为女性),中位年龄为 69.5 岁(IQR,61.3-73.8)。fCSA 和 FI 与 EIM 读数均无显著相关性,无论频率如何。所有频率的 EIM 读数均与皮下厚度、回声或真皮厚度相关。使用当前方法学,EIM 不能作为 MRI 评估肌肉质量的有效替代方法,因为它受真皮和皮下层的强烈影响。需要进一步的研究来完善方法学并确认我们的结果。