Department of Neurology, Cardinal Tien Hospital, New Taipei, Taiwan.
Department of Long-Term Care, National Taipei University of Nursing and Health Sciences, Taipei, Taiwan.
Geriatr Nurs. 2024 May-Jun;57:91-95. doi: 10.1016/j.gerinurse.2024.04.004. Epub 2024 Apr 10.
Reliability of the Short Physical Performance Battery (SPPB) are rarely examined among older adults with mild cognitive impairment (MCI). This study aimed to investigate the test-retest reliability and minimal detectable change (MDC) of the SPPB in older adults with MCI.
Participants included 100 older adults with MCI. The SPPB was assessed with the first 2 assessments separated by a 20-min interval and the third separated by a 1-week interval. The intraclass correlation coefficient (ICC) and MDC values were estimated.
The intraday ICC was 0.73 for the SPPB score, 0.90 for the 4-m walk time (4mwt), and 0.95 for the 5-times chair stand time (5cst); the corresponding interday ICC values were 0.76, 0.89, and 0.91, respectively. The MDC values ranged from 1.1 to 1.2 for the SPPB score, from 0.77 to 0.80 s for the 4mwt, and from 1.32 to 1.77 for the 5cst.
The SPPB had satisfactory reliability among older adults with MCI. The test-retest reliability of the SPPB is sufficient (>0.7) for group comparisons. Moreover, the test-retest reliability for the 4mwt and 5cst subscale performances is acceptable (> 0.9) for individual-level measurements over time.
轻度认知障碍(MCI)老年人的简短体能测试电池(SPPB)的可靠性很少被检测到。本研究旨在调查 MCI 老年人 SPPB 的重测信度和最小可检测变化(MDC)。
参与者包括 100 名 MCI 老年人。SPPB 在 20 分钟的间隔内进行了前两次评估,第三次评估间隔为 1 周,使用 SPPB 进行评估。估计了组内相关系数(ICC)和 MDC 值。
SPPB 评分的日内 ICC 为 0.73,4 米步行时间(4mwt)为 0.90,5 次椅子站立时间(5cst)为 0.95;相应的日间 ICC 值分别为 0.76、0.89 和 0.91。SPPB 评分的 MDC 值范围为 1.1 至 1.2,4mwt 的 MDC 值范围为 0.77 至 0.80 秒,5cst 的 MDC 值范围为 1.32 至 1.77。
SPPB 在 MCI 老年人中具有良好的可靠性。SPPB 的重测信度对于组间比较是足够的(>0.7)。此外,4mwt 和 5cst 子量表表现的重测信度对于个体水平的时间测量是可接受的(>0.9)。