Suppr超能文献

中国526家临床实验室血浆肾素和醛固酮检测现状洞察

Insight into the status of plasma renin and aldosterone measurement: findings from 526 clinical laboratories in China.

作者信息

Zhou Weiyan, Deng Yuhang, Ma Wenjun, Zhao Haijian, Wang Kaijun, Zhang Qian, Gan Wei, Chen Wenxiang, Cai Jun, Zhang Chuanbao

机构信息

12501 National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/ National Center of Gerontology, Beijing, P.R. China.

National Center for Cardiovascular Diseases & Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, P.R. China.

出版信息

Clin Chem Lab Med. 2024 May 1;62(11):2233-2241. doi: 10.1515/cclm-2024-0373. Print 2024 Oct 28.

Abstract

OBJECTIVES

Accurate measurements of renin and aldosterone levels play an important role in primary aldosteronism screening, which is of great importance in the management and categorization of hypertension. The objective of this study is to investigate the current status of plasma renin and aldosterone measurements in China, which is achieved by analyzing the results of 526 clinical laboratories nationwide for three pooled fresh plasma samples derived from more than 2,000 patients.

METHODS

Renin and aldosterone in three pooled plasma samples were measured four times in 526 laboratories employing various measurement systems. The inter- and intra-laboratory %CV were calculated and compared. To determine the source of the substantial inter-laboratory %CV, laboratories were categorized according to the measurement systems they are using, and both the inter- and intra-measurement-system %CV were calculated and compared.

RESULTS

Regarding renin, the majority of laboratories use four primary commercial immunoassays. However, for aldosterone, in addition to commercial immunoassays, laboratory-developed liquid chromatography-tandem mass spectrometry (LC-MS) methods are also used by laboratories. The median values of intra-laboratory %CVs, intra-measurement-system %CVs, inter-laboratory %CVs, and inter-measurement systems %CVs varied between 1.6 and 2.6 %, 4.6 and 14.9 %, 8.3 and 25.7 %, and 10.0 and 34.4 % for renin, respectively. For aldosterone, these values ranged from 1.4 to 2.2 %, 2.5-14.7 %, 9.9-31.0 %, and 10.0-35.5 %, respectively.

CONCLUSIONS

The precision within laboratories and measurement systems for plasma renin and aldosterone measurements is satisfactory. However, the comparability between laboratories using different measurement systems remains lacking, indicating the long way to achieve standardization and harmonization for these two analytes.

摘要

目的

准确测量肾素和醛固酮水平在原发性醛固酮增多症筛查中起着重要作用,这对高血压的管理和分类至关重要。本研究的目的是调查中国血浆肾素和醛固酮测量的现状,通过分析全国526家临床实验室对来自2000多名患者的三份混合新鲜血浆样本的检测结果来实现。

方法

526家实验室使用各种测量系统对三份混合血浆样本中的肾素和醛固酮进行了四次测量。计算并比较了实验室间和实验室内的变异系数百分比(%CV)。为了确定实验室间%CV差异较大的原因,根据实验室使用的测量系统对其进行分类,并计算和比较了测量系统间和测量系统内的%CV。

结果

关于肾素,大多数实验室使用四种主要的商业免疫测定法。然而,对于醛固酮,除了商业免疫测定法外,实验室还使用自行开发的液相色谱 - 串联质谱(LC-MS)方法。肾素的实验室内%CV、测量系统内%CV、实验室间%CV和测量系统间%CV的中位数分别在1.6%至2.6%、4.6%至14.9%、8.3%至25.7%和10.0%至34.4%之间。对于醛固酮,这些值分别在1.4%至2.2%、2.5%至14.7%、9.9%至31.0%和10.0%至35.5%之间。

结论

血浆肾素和醛固酮测量在实验室和测量系统内的精密度令人满意。然而,使用不同测量系统的实验室之间的可比性仍然缺乏,这表明实现这两种分析物的标准化和协调还有很长的路要走。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验