Suppr超能文献

经皮房间隔缺损封堵术中心脏三维经食管超声心动图测量 ASD 大小参数与球囊测量方法的比较。

Three-dimensional transesophageal echocardiography measurements of ASD sizing parameters in comparison to balloon sizing method in percutaneous ASD closure.

机构信息

Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran, Iran.

Department of Advanced Echocardiography, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.

出版信息

Echocardiography. 2024 Jun;41(6):e15822. doi: 10.1111/echo.15822.

Abstract

BACKGROUND

Balloon sizing (BS) has been used for device size selection in percutaneous atrial septal defect (ASD) closure. Due to its limitations, alternative imaging techniques like three-dimensional transesophageal echocardiography (3D-TEE) are valuable for guiding ASD device size selection during ASD closure procedures. The purpose of this study was to compare ASD sizing using measurements obtained from 3D-TEE to those utilizing the standard balloon sizing method.

METHODS

We identified 53 patients with single secundum type ASD without PFO who underwent percutaneous closure at the Tehran Heart Center between 2019 and 2022. Balloon sizing was performed in all patients with the stop-flow technique, and the choice of device size was determined based on the sizing derived from BS. 3D-TEE imaging was performed before the intervention, and the ASD shape and quality of ASD rims were assessed.

RESULTS

Among the 53 patients who underwent single ASD device closure, multiple 3D TEE measurements significantly correlated with balloon sizing results. This included defect area, perimeter, and diameter obtained from 3D-TEE images multi-planar reconstruction. ASD perimeter detected by 3D TEE had the best correlation with BS results. When divided by the shape of ASD, there was no significant difference between our 3D-images data and BS in round or oval-shaped ASDs.

CONCLUSION

The 3D-TEE study is reliable for assessing ASD configurational characteristics in percutaneous device closure candidates. 3D-TEE has the potential to accurately determine the appropriate device size and reduce complications, costs, and procedural duration. Further research is needed to validate these findings and establish the role of 3D-TEE measurements in guiding the best treatment decisions for ASD closure.

摘要

背景

球囊测量(BS)已用于经皮房间隔缺损(ASD)封堵中的器械尺寸选择。由于其局限性,替代成像技术如三维经食管超声心动图(3D-TEE)对于指导 ASD 封堵术中 ASD 器械尺寸选择具有重要价值。本研究的目的是比较使用 3D-TEE 测量值与使用标准球囊测量方法进行 ASD 测量的结果。

方法

我们确定了 2019 年至 2022 年期间在德黑兰心脏中心接受经皮封堵的 53 例无房间隔缺损(PFO)的单一继发孔型 ASD 患者。所有患者均采用停流技术进行球囊测量,根据 BS 得出的尺寸选择器械尺寸。在介入前进行 3D-TEE 成像,并评估 ASD 形状和 ASD 边缘质量。

结果

在接受单一 ASD 器械封堵的 53 例患者中,3D-TEE 的多项测量值与球囊测量结果显著相关。这包括从 3D-TEE 图像多平面重建获得的缺陷面积、周长和直径。3D-TEE 检测到的 ASD 周长与 BS 结果相关性最好。按 ASD 形状划分,在圆形或椭圆形 ASD 中,我们的 3D 图像数据与 BS 之间无显著差异。

结论

3D-TEE 研究可用于评估经皮器械封堵候选者的 ASD 形态特征。3D-TEE 有可能准确确定合适的器械尺寸,减少并发症、成本和手术时间。需要进一步研究来验证这些发现,并确定 3D-TEE 测量在指导 ASD 封堵最佳治疗决策中的作用。