Universidade de São Paulo, Faculdade de Odontologia, Departamento de Ortodontia (São Paulo/SP, Brazil).
Universidade Estadual do Rio de Janeiro, Faculdade de Odontologia, Departamento de Ortodontia (Rio de Janeiro/RJ, Brazil).
Dental Press J Orthod. 2024 Jun 10;29(2):e2423212. doi: 10.1590/2177-6709.29.2.e2423212.oar. eCollection 2024.
The purpose of this retrospective study was to compare accuracy of arch expansion using two different thermoplastic materials in Invisalign aligners: EX30® (Polyethylene Terephthalate Glycol, or PETG) and SmartTrack® (polyurethane).
The study sample comprised 65 adult patients consecutively treated with Invisalign from two private practices: group 1 - treated with EX30® (358 teeth) and group 2 - treated with SmartTrack® (888 teeth). Six hundred and twenty-three measurements were assessed in three digital models throughout treatment: model 1 - initial, model 2 - predicted tooth position, and model 3 - achieved position. Sixteen reference points per arch were marked and, after best alignment, 2 points per tooth were copied from one digital model to another. Linear values of both arches were measured for canines, premolars, and first molars: on lingual gingival margins and cusp tips of every tooth. Comparisons were performed by Wilcoxon and Mann-Whitney test.
Both termoplastic materials presented significant differences between predicted and achieved values for all measurements, except for the lower molar cusp tip in the SmartTrack® group. There is no statistical difference in the accuracy of transverse expansion between these two materials. Overall accuracy for EX30® aligners in maxilla and mandible were found to be 37 and 38%, respectively; and Smarttrack® presented an overall accuracy of 56.62% in the maxilla and 68.72% in the mandible.
It is not possible to affirm one material expands better than the other. Further controlled clinical studies should be conducted comparing SmartTrack® and EX30® under similar conditions.
本回顾性研究的目的是比较两种不同热塑性材料在 Invisalign 矫治器中进行弓丝扩弓的准确性:EX30®(聚对苯二甲酸乙二醇酯,或 PETG)和 SmartTrack®(聚氨酯)。
研究样本包括来自两家私人诊所的 65 名连续接受 Invisalign 治疗的成年患者:组 1-用 EX30®治疗(358 个牙位),组 2-用 SmartTrack®治疗(888 个牙位)。在治疗过程中,共评估了三个数字模型中的 623 个测量值:模型 1-初始,模型 2-预测的牙齿位置,模型 3-达到的位置。每个弓标记了 16 个参考点,在最佳对齐后,从一个数字模型复制 2 个点到另一个模型。测量每个牙齿的弓丝的颊舌龈缘和牙尖的线值。采用 Wilcoxon 和 Mann-Whitney 检验进行比较。
两种热塑性材料在所有测量值中,除了 SmartTrack®组的下磨牙牙尖外,预测值和实际值之间均存在显著差异。这两种材料的横向扩张准确性没有统计学差异。EX30®矫治器在上颌和下颌的整体准确性分别为 37%和 38%;Smarttrack®在上颌的整体准确性为 56.62%,下颌的整体准确性为 68.72%。
不能确定一种材料比另一种材料扩张效果更好。应进行进一步的、控制良好的临床研究,比较 SmartTrack®和 EX30®在相似条件下的效果。