Suppr超能文献

连续颗粒活性炭过滤器运行对出水水质的影响。

Implications of the operation of continuous granular activated carbon filters on the effluent quality.

机构信息

Department of Civil and Environmental Engineering Sciences, Institute IWAR, Chair of Water and Environmental Biotechnology, Technical University of Darmstadt, Darmstadt, Germany.

Department of Civil and Environmental Engineering Sciences, Institute IWAR, Chair of Water and Environmental Biotechnology, Technical University of Darmstadt, Darmstadt, Germany; Mecana AG, Industriestrasse 39, 8864 Reichenburg, Switzerland.

出版信息

Water Sci Technol. 2024 Jun;89(11):3079-3092. doi: 10.2166/wst.2024.178. Epub 2024 May 30.

Abstract

Granular activated carbon (GAC) filtration is a commonly used method for advanced wastewater treatment. Filters can be operated continuously or discontinuously, with continuous operation not requiring feed flow interruption for backwashing and circulation (B/C). This study investigated the influence of B/C on the effluent quality of continuous filters. Two continuous GAC filters were operated for 1.5 years, with analysis of dissolved substances and particulate matter in the influent and effluent. The results indicated that various B/C modes had no impact on the removal of dissolved organic carbon and organic micropollutants (OMP), achieving an OMP removal of over 70% after 5,600 treated bed volumes (m treated wastewater per m GAC). However, it was evident that continuous B/C over 2-4 h resulted in increased turbidity, total suspended solids over 30 mg/L and total phosphorus concentrations of 1.3 mg/L in the filter effluent. Additionally, the study demonstrated that longer and more intensive B/C processes resulted in GAC size degradation with AC concentrations of up to 6.9 mg/L in the filter effluent, along with a change in GAC particle size. Furthermore, the importance of pre-filtration in reducing particulate matter in the filter influent and decreasing hydraulic head loss could be demonstrated.

摘要

颗粒活性炭(GAC)过滤是一种常用于高级废水处理的方法。过滤器可以连续或不连续运行,连续运行不需要中断进料流进行反冲洗和循环(B/C)。本研究考察了 B/C 对连续过滤器出水水质的影响。两个连续的 GAC 过滤器运行了 1.5 年,对进水和出水的溶解物质和颗粒物进行了分析。结果表明,各种 B/C 模式对去除溶解性有机碳和有机微污染物(OMP)没有影响,在处理了 5600 个床体积(每立方米 GAC 处理的废水)后,OMP 的去除率超过 70%。然而,连续 B/C 超过 2-4 小时会导致过滤出水的浊度增加、总悬浮固体超过 30mg/L 和总磷浓度达到 1.3mg/L。此外,研究表明,更长和更剧烈的 B/C 过程会导致 GAC 尺寸降解,过滤出水中的 AC 浓度高达 6.9mg/L,并伴随着 GAC 粒径的变化。此外,可以证明预过滤在减少过滤进水的颗粒物和降低水头损失方面的重要性。