Department of Surgery, School of Medicine of the Federal University of Ceará, Fortaleza, Brazil.
J Ultrasound Med. 2024 Nov;43(11):2039-2050. doi: 10.1002/jum.16533. Epub 2024 Jul 25.
To use three-dimensional anorectal ultrasonography (3D-US) to evaluate the outcome of ligation of the intersphincteric fistula tract (LIFT) in patients with crypto-glandular transsphincteric fistula and describing the patterns of healing, failure, and recurrence rate.
After classifying the fistula and determining the length of the sphincter muscle to be transected, the patients were submitted to LIFT. The accuracy of pre- and postoperative 3D-US with 360° endoprobe (16 MHz) with automatic scanning and clinical findings was evaluated against surgical findings. Three outcomes were considered: healing, failure (persistent anal fistula through the original external opening or intersphincteric), and recurrence (reappearance of the anal fistula).
Sixty-three patients of both sexes were evaluated. The 3D-US assessment revealed primary healing in 50 (79.3%) patients, although in 6 (9.5%) cases healing was delayed and the cavity was without communication with the anal canal. The procedure failed in 9 (15.9%) and fistula recurred in 4 (6.3%), all of whom underwent a second surgery based on a new 3D-US, resulting in a 92.3% (12/13) healing rate on 3D-US.
A 3D-US was found to be useful in the preoperative assessment of fistulas by quantifying the percentage of muscle to be transected, and in the postoperative assessment by identifying healing, types of failure, and recurrence. The 3D-US was accurate and consistent with surgical findings.
使用三维肛门直肠超声(3D-US)评估加密腺经括约肌间瘘管结扎术(LIFT)治疗加密腺经括约肌间瘘的疗效,并描述愈合、失败和复发的模式。
在对瘘管进行分类并确定要切断的括约肌长度后,对患者进行 LIFT 手术。使用带有自动扫描功能的 360°腔内探头(16MHz)的术前和术后 3D-US 的准确性,以及临床发现与手术发现进行了评估。考虑了三种结果:愈合、失败(通过原始外口或括约肌间的持续性肛痿)和复发(肛痿再次出现)。
对 63 例男女患者进行了评估。3D-US 评估显示 50 例(79.3%)患者有原发性愈合,尽管有 6 例(9.5%)愈合延迟,且腔隙与肛管无相通。9 例(15.9%)手术失败,4 例(6.3%)复发,所有患者均根据新的 3D-US 进行了第二次手术,3D-US 上的愈合率为 92.3%(12/13)。
3D-US 在术前评估瘘管时可通过量化要切断的肌肉比例,在术后评估时通过识别愈合、失败类型和复发,发现其是有用的。3D-US 准确且与手术发现一致。