Yoshimoto Yuriko, Yamaguchi Satoshi, Kimura Seiji, Kitsukawa Kaoru, Matsumoto Koji, Shiko Yuki, Horii Manato, Watanabe Shotaro, Sasho Takahisa, Ohtori Seiji
Graduate School of Medical and Pharmaceutical Sciences, Chiba University, Chiba, Japan.
Graduate School of Medical and Pharmaceutical Sciences, Chiba University, Chiba, Japan; Graduate School of Global and Transdisciplinary Studies, Chiba University, Chiba, Japan.
J Orthop Sci. 2025 May;30(3):492-498. doi: 10.1016/j.jos.2024.08.002. Epub 2024 Aug 19.
We aimed to evaluate the intra- and interrater measurement reliability of the lateral ankle ligament attachment locations using three-dimensional magnetic resonance imaging.
We analysed 54 participants with a mean age of 43 years who underwent three-dimensional ankle magnetic resonance imaging and had normal lateral ligaments. Bony landmarks of the distal fibula, talus, and calcaneus were identified in the reconstructed images. The centers of the anterior talofibular ligament and calcaneofibular ligament attachments were also identified. The distances between the landmarks and attachments were measured. Two raters performed the measurements twice, and intra- and interrater intraclass correlation coefficients were calculated.
The intrarater intraclass correlation coefficient values were between 0.71 and 0.96 for the anterior talofibular ligament attachment measurements and between 0.77 and 0.95 for the calcaneofibular ligament attachments. The interrater intraclass correlation coefficient was higher than 0.7, except for the distance between the anterior talofibular ligament superior bundle and fibular obscure tubercle. The fibular attachment of a single-bundle anterior talofibular ligament was located 13.3 mm from the inferior tip and 43% along the anterior edge of the distal fibula. The superior and inferior bundles of the double-bundle ligament were located at 43% and 23%, respectively. The calcaneofibular ligament fibular attachment was 5.5 mm from the inferior tip, at 16% along the anterior edge of the distal fibula.
The measurements of anterior talofibular ligament and calcaneofibular ligament attachment locations identified on three-dimensional magnetic resonance imaging were sufficiently reliable. This measurement method provides in vivo anatomical data on the lateral ankle ligament anatomy.
我们旨在使用三维磁共振成像评估踝关节外侧韧带附着位置的组内和组间测量可靠性。
我们分析了54名平均年龄为43岁的参与者,他们接受了三维踝关节磁共振成像检查且外侧韧带正常。在重建图像中确定腓骨远端、距骨和跟骨的骨性标志。还确定了距腓前韧带和跟腓韧带附着点的中心。测量标志点与附着点之间的距离。两名评估者进行两次测量,并计算组内和组间组内相关系数。
距腓前韧带附着点测量的组内组内相关系数值在0.71至0.96之间,跟腓韧带附着点的组内组内相关系数值在0.77至0.95之间。除距腓前韧带 superior bundle与腓骨隐蔽结节之间的距离外,组间组内相关系数高于0.7。单束距腓前韧带的腓骨附着点位于距下尖端13.3毫米处,沿腓骨远端前缘的43%处。双束韧带的 superior和 inferior束分别位于43%和23%处。跟腓韧带的腓骨附着点距下尖端5.5毫米,位于腓骨远端前缘的16%处。
在三维磁共振成像上确定的距腓前韧带和跟腓韧带附着位置的测量具有足够的可靠性。这种测量方法提供了踝关节外侧韧带解剖结构的体内解剖数据。