Suppr超能文献

冷链中断对冷藏鸡肉微生物状况的影响。

The effect of cold chain disruption on the microbiological profile of chilled chicken meat.

作者信息

Necidová Lenka, Zouharová Alena, Haruštiaková Danka, Bursová Šárka, Bartáková Klára, Golian Jozef

机构信息

Department of Animal Origin Food & Gastronomic Sciences, Faculty of Veterinary Hygiene and Ecology, University of Veterinary Sciences Brno, 61242 Brno, Czech Republic.

Department of Animal Origin Food & Gastronomic Sciences, Faculty of Veterinary Hygiene and Ecology, University of Veterinary Sciences Brno, 61242 Brno, Czech Republic.

出版信息

Poult Sci. 2024 Dec;103(12):104290. doi: 10.1016/j.psj.2024.104290. Epub 2024 Sep 2.

Abstract

This study evaluates the influence of inadequate transport conditions on the microbiological quality of chilled chicken meat packaged in plain and modified atmosphere packaging (MAP). The experiments simulated the temperature increase during sample transport to 8, 11, 14, 17, 20, and 25°C with exposure times of 1, 2, 3, and 4 h. Aerobic plate count (APC), psychrotrophic microorganisms count (PMC), β-D-glucuronidase-positive Escherichia coli, and Salmonella spp. were evaluated immediately after the exposure to the elevated temperature (0 h), 3 h, and 24 h after the return to the temperature of ≤4°C. The upper acceptable limits for APC and PMC were set for each combination of investigated chicken meat and packaging type, taking also the initial bacterial condition into account. Chilled chicken breast samples in plain packaging exceeded the APC limits in 16 cases and PMC limits in 20 cases when exposed to temperatures of >4°C, while only 2 MAP samples exceeded APC limits and 8 samples PMC limits, respectively. In chicken legs, 8 samples in plain packaging exceeded the APC limits and 15 the PMC limits, while 12 samples in MAP exceeded the APC limits and 19 the PMC limits. In 402 samples (31.9%) in which the presence of E. coli was detected, its amount ranged from 1.70 to 3.65 log CFU.g. It was more commonly detected in chicken legs (255 of 630; 40.5%) than chicken breasts (147 of 630; 23.3%) but was not related to exposure temperature, exposure time, or time until examination. The presence of Salmonella spp. was not detected in any of the samples. Data acquired in the presented study will be used in the development of software helping the national supervisory authorities in the Czech Republic to evaluate whether inadequate transport of samples to analytical laboratories could have affected the microbiological profile of the sample.

摘要

本研究评估了运输条件不佳对采用普通包装和气调包装(MAP)的冷藏鸡肉微生物质量的影响。实验模拟了样品运输过程中温度升高至8、11、14、17、20和25°C,暴露时间为1、2、3和4小时。在暴露于高温后(0小时)、恢复到≤4°C温度3小时和24小时后,对需氧平板计数(APC)、嗜冷微生物计数(PMC)、β-D-葡萄糖醛酸酶阳性大肠杆菌和沙门氏菌属进行评估。针对所研究的鸡肉和包装类型的每种组合,设定了APC和PMC的可接受上限,同时考虑了初始细菌状况。当暴露于>4°C的温度时,普通包装的冷藏鸡胸肉样品有16例超过APC限值,20例超过PMC限值,而气调包装样品分别只有2例超过APC限值和8例超过PMC限值。在鸡腿中,普通包装的8个样品超过APC限值,15个超过PMC限值,而气调包装的12个样品超过APC限值,19个超过PMC限值。在检测到大肠杆菌的402个样品(31.9%)中,其数量范围为1.70至3.65 log CFU/g。在鸡腿中(630个中有255个;40.5%)比鸡胸中(630个中有147个;23.3%)更常检测到,但与暴露温度、暴露时间或检查前时间无关。在任何样品中均未检测到沙门氏菌属。本研究获得的数据将用于开发软件,以帮助捷克共和国国家监管当局评估样品运输至分析实验室不当是否会影响样品的微生物特征。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验