Li Yue, Ma Xiaobao, Shen Jiali, Wang Wei, Wang Lu, Sun Jin, He Kuan, Chen Xiangping, Yang Jun, Chen Jianyong
Department of Otorhinolaryngology Head and Neck Surgery,Xinhua Hospital,Shanghai Jiaotong University School of Medicine;Shanghai Jiaotong University School of Medicine Ear Institute;Shanghai Key Laboratory of Translational Medicine on Ear and Nose diseases,Shanghai,200092,China.
Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. 2024 Oct;38(10):951-955. doi: 10.13201/j.issn.2096-7993.2024.10.013.
To establish the normal values of subjective visual horizontal(SVH) under different head tilt angles, analyze the test-retest reliability, and provide a normal value reference for the refined diagnosis and functional assessment of SVH in clinical vestibular disorders. Thirty-one healthy young people were selected to wear visual reality glasses to test SVH data in five different head tilt angles: upright head position 0°, head tilted 45°to the left(L45°), head tilted 45° to the right(R45°), head tilted 90° to the left(L90°), and head tilted 90° to the right(R90°), and were re-tested 2 weeks later. ①The normal values of SVH at 0°, L45°, R45°, L90°, and R90°were 0.30±1.32, 5.94±5.54, -11.44±5.32, -0.87±8.63, -2.70±8.02, respectively. ②The 95% confidence intervals of SVH at 0°, L45°, R45°, L90°, and R90° were: (-2.34,2.94),(-5.14,17.02),(-22.08,-0.80),(-18.13,16.39),(-18.74,13.34), respectively. The ratio of asymmetry in the absolute value of bilateral 45° deviation was 26.4% and the ratio of asymmetry in the absolute value of bilateral 90° deviation was 1.3%. ③The intra-class correlation coefficient(ICC) for 0°, L45°, R45°, L90° and R90° was 0.625, 0.641, 0.564, 0.769, 0.656, respectively. SVH has good test-retest reliability and high clinical test stability and stability. The data on normal values of SVH at different head tilt angles established in this study can provide clinical references for the refined diagnosis and functional assessment of vestibular system disorders.
为建立不同头部倾斜角度下主观视觉水平(SVH)的正常值,分析重测信度,并为临床前庭疾病中SVH的精准诊断和功能评估提供正常值参考。选取31名健康年轻人,佩戴虚拟现实眼镜,测量其在5种不同头部倾斜角度下的SVH数据,分别为:头部直立0°、向左倾斜45°(L45°)、向右倾斜45°(R45°)、向左倾斜90°(L90°)和向右倾斜90°(R90°),并在2周后进行复测。①0°、L45°、R45°、L90°和R90°时SVH的正常值分别为0.30±1.32、5.94±5.54、-11.44±5.32、-0.87±8.63、-2.70±8.02。②0°、L45°、R45°、L90°和R90°时SVH的95%置信区间分别为:(-2.34,2.94)、(-5.14,17.02)、(-22.08,-0.80)、(-18.13,16.39)、(-18.74,13.34)。双侧45°偏差绝对值的不对称率为26.4%,双侧90°偏差绝对值的不对称率为1.3%。③0°、L45°、R45°、L90°和R90°时的组内相关系数(ICC)分别为0.625、0.641、0.564、0.769、0.656。SVH具有良好的重测信度和较高的临床测试稳定性。本研究建立的不同头部倾斜角度下SVH正常值的数据可为前庭系统疾病的精准诊断和功能评估提供临床参考。