Suppr超能文献

病例报告:一种新型的无针经房间隔穿刺方法。

Case Report: A novel method of needle-free transseptal puncture.

作者信息

Lee Chia-Chen, Chao Chen-An, Chang Su-Huan, Chen Chun-Kai, Chen Yen-Siou, Lin Chang-En, Jeng Tsung-Ping, Yu Chih-Chieh

机构信息

Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan.

Division of Cardiology, Department of Internal Medicine, National Taiwan University College of Medicine and Hospital, Taipei, Taiwan.

出版信息

Front Cardiovasc Med. 2024 Dec 3;11:1493240. doi: 10.3389/fcvm.2024.1493240. eCollection 2024.

Abstract

BACKGROUND

In the era of fluoroless catheter ablation (CA), achieving a successful transseptal puncture (TSP) presents a significant challenge. We introduce a novel technique for zero-fluoroscopy and cost-effective needle-free TSP.

CASE SUMMARY

We describe two cases where a GMS-1 guidewire (0.025 inch, pigtail configuration; Toray Medical Co., Ltd., Japan) was utilized for TSP. This technique was performed using either fluoroscopy or intracardiac echocardiography (ICE). The procedure was completed successfully in both cases, with no complications reported.

CONCLUSION

The use of a 0.025 inch GMS-1 guidewire with an electrocautery technique enables effective transseptal puncture without the need for a needle or fluoroscopy. This novel approach offers a safe, efficient, and zero-fluoroscopic alternative for TSP.

摘要

背景

在无荧光导管消融(CA)时代,成功进行经房间隔穿刺(TSP)是一项重大挑战。我们介绍一种用于零荧光且经济高效的无针TSP的新技术。

病例总结

我们描述了两例使用GMS-1导丝(0.025英寸,猪尾形;日本东丽医疗株式会社)进行TSP的病例。该技术使用荧光透视或心腔内超声心动图(ICE)进行。两例均成功完成手术,未报告并发症。

结论

使用0.025英寸GMS-1导丝结合电灼技术可实现有效的经房间隔穿刺,无需使用针头或荧光透视。这种新方法为TSP提供了一种安全、高效且零荧光的替代方案。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b414/11649652/30fc888f53d4/fcvm-11-1493240-g001.jpg

相似文献

1
Case Report: A novel method of needle-free transseptal puncture.
Front Cardiovasc Med. 2024 Dec 3;11:1493240. doi: 10.3389/fcvm.2024.1493240. eCollection 2024.
2
Safety and Effectiveness of a Novel Fluoroless Transseptal Puncture Technique for Lead-free Catheter Ablation: A Case Series.
J Innov Card Rhythm Manag. 2020 Apr 15;11(4):4079-4085. doi: 10.19102/icrm.2020.110405. eCollection 2020 Apr.
3
The safety and efficiency of fluoroless site-specific transseptal puncture guided by three-dimensional intracardiac echocardiography.
J Interv Card Electrophysiol. 2022 Dec;65(3):643-649. doi: 10.1007/s10840-022-01298-7. Epub 2022 Jul 8.
5
Intracardiac echocardiography-guided transseptal puncture for fluoroless catheter ablation of left-sided tachycardias.
J Interv Card Electrophysiol. 2021 Sep;61(3):595-602. doi: 10.1007/s10840-020-00858-z. Epub 2020 Aug 28.
7
Intracardiac echocardiography guided electrified J-wire trans-septal puncture: A prospective randomized controlled trial.
Pacing Clin Electrophysiol. 2024 Mar;47(3):448-454. doi: 10.1111/pace.14916. Epub 2024 Jan 30.
8
Mediguide-Assisted Transseptal Puncture without Echocardiographic Guidance.
Pacing Clin Electrophysiol. 2017 May;40(5):545-550. doi: 10.1111/pace.13039. Epub 2017 Apr 25.
9
Fluoroscopy-free Atrial Transseptal Puncture.
Eur J Arrhythm Electrophysiol. 2016 Winter;2(2):57-61. doi: 10.17925/EJAE.2016.02.02.57.
10
Off the pedal: Fluoroless transseptal puncture in pediatric supraventricular tachycardia ablation.
Pacing Clin Electrophysiol. 2017 Nov;40(11):1254-1259. doi: 10.1111/pace.13195. Epub 2017 Oct 9.

本文引用的文献

1
Intracardiac echocardiography guided electrified J-wire trans-septal puncture: A prospective randomized controlled trial.
Pacing Clin Electrophysiol. 2024 Mar;47(3):448-454. doi: 10.1111/pace.14916. Epub 2024 Jan 30.
2
Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation.
N Engl J Med. 2023 Nov 2;389(18):1660-1671. doi: 10.1056/NEJMoa2307291. Epub 2023 Aug 27.
3
First experience with a transseptal puncture using a novel transseptal crossing device with integrated dilator and needle.
J Interv Card Electrophysiol. 2022 Dec;65(3):731-737. doi: 10.1007/s10840-022-01329-3. Epub 2022 Aug 9.
4
Comparing the safety and effectiveness of dedicated radiofrequency transseptal wires to electrified metal guidewires.
J Cardiovasc Electrophysiol. 2022 Mar;33(3):371-379. doi: 10.1111/jce.15341. Epub 2022 Jan 11.
5
Transseptal puncture: procedural guidance, challenging situations and management of complications.
EuroIntervention. 2021 Oct 20;17(9):720-727. doi: 10.4244/EIJ-D-20-00454.
6
Cryoablation or Drug Therapy for Initial Treatment of Atrial Fibrillation.
N Engl J Med. 2021 Jan 28;384(4):305-315. doi: 10.1056/NEJMoa2029980. Epub 2020 Nov 16.
7
Cryoballoon Ablation as Initial Therapy for Atrial Fibrillation.
N Engl J Med. 2021 Jan 28;384(4):316-324. doi: 10.1056/NEJMoa2029554. Epub 2020 Nov 16.
9
Guidewire electrosurgery-assisted trans-septal puncture.
Catheter Cardiovasc Interv. 2018 May 1;91(6):1164-1170. doi: 10.1002/ccd.27311. Epub 2017 Sep 20.
10
Fluoroless Catheter Ablation of Cardiac Arrhythmias: A 5-Year Experience.
Pacing Clin Electrophysiol. 2017 Apr;40(4):425-433. doi: 10.1111/pace.13038. Epub 2017 Mar 3.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验