基于1.5-T磁共振成像的R2*法测量肝脏铁浓度的可重复性:一项荟萃分析。

Reproducibility of liver iron concentration measured by R2* method based on 1.5-T MRI: a meta-analysis.

作者信息

Cao Sue, Zhang Jie, Dong Chenyu, Que Yutao, Gao Xin, Guo Ruomi

机构信息

Department of Radiology, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China.

出版信息

Eur Radiol. 2025 Jan 3. doi: 10.1007/s00330-024-11334-x.

Abstract

OBJECTIVES

To explore the reproducibility of the 1.5-T MR imaging (MRI)-based R2* method in measuring the liver iron concentration (LIC) across different MRI scanners, scan parameters, and postprocessing techniques.

MATERIALS AND METHODS

We performed a systematic search of the PubMed, Embase, Medline, Cochrane Library, and Web of Science databases and identified studies that used the 1.5-T MRI-based R2* method to measure the LIC. The original data were extracted from the selected studies. Reproducibility was assessed in terms of the ability to replicate the measured LIC with the 1.5-T MRI-based R2* method across different scanning instruments, scan parameters, and postprocessing techniques. We used the scanner equipment, scan parameters, and postprocessing technique as random effects to determine whether the R2* values obtained in the different studies were significantly different after the effects of the measured LIC were excluded. The calibration curve that best fit the R2* value to the LIC was estimated via univariate regression.

RESULTS

Twenty-one studies (1147 participants) were included. The seven studies (435 participants) in which the initial TE was ≤ 1.0 ms and the TE spacing was ≤ 1.4 ms did not have significant differences in the measured R2* value in pairwise comparisons (p > 0.05). Calibration of R2* to LIC was as follows: LIC (mg/g) = 0.042 + 2.85 × 10 R2* (s) (R = 0.79).

CONCLUSION

The 1.5-T MRI-based R2* method in estimating LIC was reproducible across different MRI scanners, scan parameters, and postprocessing techniques.

KEY POINTS

Question The R2* method is widely used to quantify LIC, but the reproducibility of R2*-based LIC estimation remains unknown. Findings In scan sequences with an initial echo time (TE) ≤ 1.0 ms and a TE spacing ≤ 1.4 ms, the R2*-based LIC quantification at 1.5 T achieved good reproducibility. Clinical relevance The 1.5-T MRI-based R2* method enables reproducible quantification of the LIC; its reproducibility spares patients from unnecessary trauma and economic burdens while promoting the extensive clinical dissemination of R2*-based LIC quantification methods.

摘要

目的

探讨基于1.5-T磁共振成像(MRI)的R2*方法在不同MRI扫描仪、扫描参数和后处理技术下测量肝脏铁浓度(LIC)的可重复性。

材料与方法

我们对PubMed、Embase、Medline、Cochrane图书馆和Web of Science数据库进行了系统检索,确定了使用基于1.5-T MRI的R2方法测量LIC的研究。从选定的研究中提取原始数据。通过在不同扫描仪器、扫描参数和后处理技术下,使用基于1.5-T MRI的R2方法复制测量的LIC的能力来评估可重复性。我们将扫描仪设备、扫描参数和后处理技术作为随机效应,以确定在排除测量的LIC的影响后,不同研究中获得的R2值是否有显著差异。通过单变量回归估计最适合R2值与LIC的校准曲线。

结果

纳入21项研究(1147名参与者)。在初始回波时间(TE)≤1.0 ms且TE间距≤1.4 ms的7项研究(435名参与者)中,两两比较时测量的R2值无显著差异(p>0.05)。R2与LIC的校准如下:LIC(mg/g)=0.042+2.85×10R2*(s)(R=0.79)。

结论

基于1.5-T MRI的R2*方法在不同MRI扫描仪、扫描参数和后处理技术下估计LIC具有可重复性。

关键点

问题R2方法广泛用于量化LIC,但基于R2的LIC估计的可重复性仍然未知。发现:在初始回波时间(TE)≤1.0 ms且TE间距≤1.4 ms的扫描序列中,基于1.5 T的R2LIC定量具有良好的可重复性。临床意义:基于1.5-T MRI的R2方法能够对LIC进行可重复的定量;其可重复性使患者免受不必要的创伤和经济负担,同时促进基于R2*的LIC定量方法的广泛临床传播。