Fernández Joaquín, Burguera Noemí, Calvo-de-Mora Marina Rodríguez, Rocha-de-Lossada Carlos, Rodríguez-Vallejo Manuel
J Refract Surg. 2025 Apr;41(4):e291-e299. doi: 10.3928/1081597X-20250213-01. Epub 2025 Apr 1.
To evaluate the impact of corneal aberrations on the visual performance of patients who received a multifocal intraocular lens (MIOL) implant.
Two hundred seventy patients who underwent cataract or refractive lens exchange and were implanted with an apodized diffractive MIOL were included in the analysis. Relationships between total higher order aberrations (HOAs), coma, trefoil, and spherical aberration (SA) measured with a Scheimpflug topographer at 4 mm versus visual acuity and contrast sensitivity areas under the defocus curves (AUC) were evaluated. Relationships between other demographic and biometric variables with total AUCs were also explored.
Eyes rarely showed coma and trefoil aberrations exceeding 0.2 μm, 0.1 μm for SA, and 0.3 μm for the total HOAs. The total HOAs showed correlations with age (rho = 0.32, < .0005) and anterior chamber depth (rho = -0.21, = .001). The mesopic pupil size, age, and chart luminance, in the following order, were mainly correlated with total AUCs. A correction by mesopic pupil was required to unmask weak correlations of AUCs with the corneal aberrations. These were found particularly for total HOAs and total and near AUCs ( < .05).
Values below 0.3 μm for total HOAs, 0.2 μm for coma and trefoil, and 0.1 μm for SA at 4 mm are safe for the study IOL. Higher values are rare but still can be safe, and the 0.5 μm cut-off at 4 mm for contraindication merits further research with this and other IOLs. .
评估角膜像差对接受多焦点人工晶状体(MIOL)植入患者视觉性能的影响。
分析纳入了270例行白内障或屈光性晶状体置换并植入了变迹衍射MIOL的患者。评估了使用Scheimpflug地形图仪在4mm处测量的总高阶像差(HOAs)、彗差、三叶草像差和球差(SA)与视力及散焦曲线下对比敏感度面积(AUC)之间的关系。还探讨了其他人口统计学和生物测量变量与总AUC之间的关系。
眼睛很少出现彗差和三叶草像差超过0.2μm、SA超过0.1μm以及总HOAs超过0.3μm的情况。总HOAs与年龄(rho = 0.32,P <.0005)和前房深度(rho = -0.21,P =.001)相关。中视瞳孔大小、年龄和图表亮度按此顺序主要与总AUC相关。需要进行中视瞳孔校正以揭示AUC与角膜像差之间的弱相关性。这些相关性在总HOAs以及总AUC和近视力AUC中尤为明显(P <.05)。
对于本研究中的人工晶状体,4mm处总HOAs低于0.3μm、彗差和三叶草像差低于0.2μm以及SA低于0.1μm的值是安全的。更高的值很少见但仍可能是安全的,4mm处0.5μm的截断值作为禁忌证值得对该人工晶状体和其他人工晶状体进一步研究。