Stehbens W E, Fee C J
Angiology. 1985 Jul;36(7):442-51. doi: 10.1177/000331978503600706.
The dye injection technique was used to study flow patterns in ten U-bends and two helical coils. These models were manufactured of glass and designed to simulate abnormal arterial configurations in man. In each model flow disturbances were observed below the critical Reynolds number of 2000 for flow in a straight tube with one reading as low as 250. The disturbances in the flow were sensitive to external disturbances. Their periodicity was relatively regular but the frequency increased with augmentation of flow rates and some irregularity was apparent. The results indicate that they could have applicability to the human vascular system.
采用染料注射技术研究了十个U形弯管和两个螺旋盘管中的流动模式。这些模型由玻璃制成,旨在模拟人体异常动脉结构。在每个模型中,当直管内流动的临界雷诺数低于2000时就观察到了流动扰动,其中一个读数低至250。流动中的扰动对外部干扰很敏感。它们的周期性相对规则,但频率随着流速的增加而增加,并且明显存在一些不规则性。结果表明,它们可能适用于人体血管系统。