Suppr超能文献

Glean尿动力学系统的可行性与安全性:现代尿动力学系统疗效研究

The Feasibility and Safety of the Glean Urodynamics System: The Modern Urodynamics System Efficacy Study.

作者信息

Kim Jason, Xavier Keith, Cannon-Smith Tracy, Vaughan Taylor, Vemulapalli Sreenivas, Zhao Hanson, Aalami-Harandi Arshia, Shah Nemi

机构信息

Stony Brook Medicine, East Setauket, New York, USA.

Urology Partners of North Texas, Arlington, Texas, USA.

出版信息

J Endourol. 2025 Jun;39(6):625-634. doi: 10.1089/end.2025.0270. Epub 2025 May 2.

Abstract

Urodynamics is used to diagnose lower urinary tract dysfunction; however, conventional urodynamics results often poorly correlate to patient symptoms because of the nonphysiological nature of the test. The Glean Urodynamics System is a novel, wireless, catheter-free ambulatory urodynamics system that allows clinicians to study lower urinary tract dysfunction in a more physiological manner. The objective of this study was to evaluate the feasibility, efficacy, and safety of the Glean Urodynamics System for use in clinic. This prospective, single-arm, multicenter interventional trial enrolled adults with lower urinary tract dysfunction. Participants underwent conventional urodynamics per standard of care followed by ambulatory urodynamics using the intravesical Glean bladder sensor. After the removal of the Glean sensor, participants completed comfort and preference questionnaires. Participants were followed up within 7-14 days to assess the incidence of adverse events. Thirty-eight participants were enrolled. Glean sensor insertion was attempted in 33 participants and successful in 32 (97.0%). The median sensor insertion time was 33.62 seconds (range: 12.32-256). The Glean Urodynamics System recorded vesical pressure, and all 32 participants were able to void with the sensor indwelling. Median sensor removal time was 5.71 seconds (range: 0.79-22.15). There were 14 adverse events in 12 participants, of which 7 events (in 7 participants) were attributed to the Glean Urodynamics System. There were no serious adverse events. Overall participant feedback on the Glean Urodynamics System was positive, and clinicians reported it was easy to use. The Glean Urodynamics System is a feasible, efficacious, safe, and well-tolerated device that enables ambulatory urodynamics with physiological bladder filling and without catheters impeding lower urinary tract function.

摘要

尿动力学用于诊断下尿路功能障碍;然而,由于该检查的非生理性,传统尿动力学结果往往与患者症状相关性较差。Glean尿动力学系统是一种新型的、无线的、无需导尿管的动态尿动力学系统,它使临床医生能够以更符合生理的方式研究下尿路功能障碍。本研究的目的是评估Glean尿动力学系统在临床应用中的可行性、有效性和安全性。这项前瞻性、单臂、多中心干预试验纳入了患有下尿路功能障碍的成年人。参与者按照标准护理流程接受传统尿动力学检查,随后使用膀胱内Glean膀胱传感器进行动态尿动力学检查。在移除Glean传感器后,参与者完成舒适度和偏好问卷。在7至14天内对参与者进行随访,以评估不良事件的发生率。共招募了38名参与者。33名参与者尝试插入Glean传感器,32名成功插入(97.0%)。传感器插入的中位时间为33.62秒(范围:12.32 - 256秒)。Glean尿动力学系统记录膀胱压力,所有32名参与者在传感器留置期间都能够排尿。传感器移除的中位时间为5.71秒(范围:0.79 - 22.15秒)。12名参与者发生了14起不良事件,其中7起事件(7名参与者)归因于Glean尿动力学系统。没有严重不良事件。参与者对Glean尿动力学系统的总体反馈是积极的,临床医生报告该系统易于使用。Glean尿动力学系统是一种可行、有效、安全且耐受性良好的设备,能够实现动态尿动力学检查,膀胱充盈符合生理状态,且没有导尿管妨碍下尿路功能。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验