Yamamoto Kento, Granek Zuzanna, Tsuboi Kenji, Yoshizawa Eisei, Tanaka Mami, Umemoto Yasutaka, Furukawa Hiroshi
From the Department of Plastic and Reconstructive Surgery, Aichi Medical University, Nagakute, Japan.
Faculty of Medicine, Medical University of Lodz, Lodz, Poland.
Plast Reconstr Surg Glob Open. 2025 Jun 11;13(6):e6869. doi: 10.1097/GOX.0000000000006869. eCollection 2025 Jun.
End-to-side venous anastomosis is a critical technique widely used in head and neck reconstructive surgery. Despite the availability of numerous vascular anastomosis training methods, a dedicated approach for practicing venous end-to-side anastomosis remains elusive. To address this gap, we introduce an innovative synthetic vascular model using a common and accessible material: the condom. It is easy to obtain, cheap, available in every country, and does not require detaching the blood vessel or processing the material. Also, because it is transparent, it is easy to recognize the suture points and check for leaks. With its remarkable ability to replicate the thickness and elasticity of the internal jugular vein, this model offers a practical and effective solution for microanastomosis training. This novel approach could enhance surgical skill development, providing a realistic and reproducible method for mastering this essential technique.
端侧静脉吻合术是头颈重建手术中广泛应用的一项关键技术。尽管有多种血管吻合训练方法,但专门用于练习静脉端侧吻合术的方法仍然难以捉摸。为了填补这一空白,我们引入了一种创新的合成血管模型,使用一种常见且容易获得的材料:避孕套。它易于获取、价格便宜,在每个国家都有,并且不需要分离血管或处理材料。此外,由于它是透明的,很容易识别缝合点并检查是否有渗漏。该模型具有出色的复制颈内静脉厚度和弹性的能力,为微血管吻合训练提供了一种实用且有效的解决方案。这种新颖的方法可以促进手术技能的发展,为掌握这项关键技术提供一种现实且可重复的方法。