Ohtani Hiroshi, Shibutani Masatsune, Tatsunari Fukuoka, Kasashima Hiroaki, Maeda Kiyoshi
Department of Gastroenterological Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan.
Department of Surgery, Ohno Memorial Hospital, Osaka, Japan.
In Vivo. 2025 Jul-Aug;39(4):2165-2175. doi: 10.21873/invivo.14012.
BACKGROUND/AIM: The anastomotic leakage rate of the double stapling technique anastomosis in colorectal surgery remains high at approximately 10%. The Echelon Circular™ powered stapler (ECPS) has been recently reported to reduce the risk of anastomotic leakage. A meta-analysis was conducted to evaluate and compare the effectiveness of ECPS to that of the manual circular stapler (MCS) in left-sided colorectal resections.
We searched publicly available literature databases for studies published between 2018 and August 2024. The following search terms were used: "powered circular stapler", "powered circular", "anastomosis", and "powered echelon". We analyzed several outcomes including anastomotic leakage, major anastomotic leakage, and anastomotic bleeding. A subgroup analysis was performed to analyze Japanese cases only.
We identified 9 papers reporting results that compared ECPS for left-sided colorectal resection with MCS. Our meta-analysis included 3,301 patients with colorectal anastomosis; 1,135 had undergone ECPS and 2,166 had undergone MCS. The overall anastomotic leakage rate was significantly lower in the ECPS group than in the MCS group (<0.0001). Regarding major anastomotic leakage, there was a tendency for the ECPS group to include fewer cases than the MCS group (=0.10). For anastomotic bleeding, no significant difference was found between the two groups. In the subgroup analysis of Japanese patients, ECPS also showed significantly lesser anastomotic leakage than MCS.
ECPS may significantly reduce the rate of anastomotic leakage in left-sided colorectal surgery compared to MCS in both the Western and Asian populations.
背景/目的:在结直肠手术中,双吻合器技术吻合的吻合口漏率仍居高不下,约为10%。最近有报道称,Echelon Circular™电动吻合器(ECPS)可降低吻合口漏的风险。进行了一项荟萃分析,以评估和比较ECPS与手动圆形吻合器(MCS)在左侧结直肠切除术中的有效性。
我们在公开可用的文献数据库中搜索了2018年至2024年8月发表的研究。使用了以下搜索词:“电动圆形吻合器”、“电动圆形”、“吻合术”和“电动阶梯式”。我们分析了几个结果,包括吻合口漏、主要吻合口漏和吻合口出血。进行了亚组分析,仅分析日本病例。
我们确定了9篇报告将左侧结直肠切除术的ECPS与MCS进行比较结果的论文。我们的荟萃分析纳入了3301例结直肠吻合患者;1135例接受了ECPS,2166例接受了MCS。ECPS组的总体吻合口漏率显著低于MCS组(<0.0001)。关于主要吻合口漏,ECPS组的病例数有少于MCS组的趋势(=0.10)。对于吻合口出血,两组之间未发现显著差异。在日本患者的亚组分析中,ECPS的吻合口漏也显著少于MCS。
与MCS相比,在西方和亚洲人群中,ECPS可能显著降低左侧结直肠手术中的吻合口漏率。