Suppr超能文献

缝线粗细对房角镜辅助小梁切开术临床结局的影响:5-0和6-0聚丙烯缝线的对比分析

Influence of suture thickness on clinical outcomes in gonioscopy-assisted transluminal trabeculotomy: a comparative analysis of 5-0 and 6-0 polypropylene sutures.

作者信息

Mirza Enver, Mirza Gunsu Deniz, Belviranli Selman, Okka Mehmet

机构信息

Department of Ophthalmology, Faculty of Medicine, Necmettin Erbakan University, Selçuklu, Konya, 42800, Turkey.

Clinic of Ophthalmology, University of Health Sciences, Beyhekim Training and Research Hospital, Selçuklu, Konya, Turkey.

出版信息

Int Ophthalmol. 2025 Jul 22;45(1):311. doi: 10.1007/s10792-025-03682-4.

Abstract

PURPOSE

To investigate the clinical results of Gonioscopy-Assisted Transluminal Trabeculotomy (GATT) performed with 5-0 or 6-0 polypropylene sutures and whether it makes a difference in anterior chamber (AC) morphology.

METHODS

The file records of patients with primary open-angle glaucoma or pseudoexfoliation glaucoma who underwent GATT with 5-0 or 6-0 polypropylene sutures were reviewed. Patients were divided into two groups (GATT with 5-0 polypropylene suture: Group 1 vs. GATT with 6-0 polypropylene suture: Group 2). The clinical results of GATT, intraocular pressure (IOP) values, and parameters measured with Pentacam HR Scheimpflug camera system including anterior chamber angle (ACA), anterior chamber depth (ACD), anterior chamber volume (ACV), central corneal thickness (CCT), and pupil diameter (PD) of two groups at preoperative period, postoperative 1st, 3rd, and 6th months were compared.

RESULTS

A total of 41 patients were included in the study (Group 1: n = 21, Group 2: n = 20). Approximately 60% reduction in IOP was detected in both groups and the rate of IOP reduction at each visit was similar between the two groups (p > 0.05 in all). It was determined that there were no differences in AC parameters including ACA, ACD, ACV, CCT, and PD at any visit in either group. (p > 0.05 in all). Also, there was no significant difference in the complication rates between the two groups.

CONCLUSION

It was observed that there were no significant differences in terms of success rate, complication rate, and the effect on AC morphology between performing GATT with 5-0 or 6-0 polypropylene sutures.

摘要

目的

探讨使用5-0或6-0聚丙烯缝线进行房角镜辅助经腔小梁切开术(GATT)的临床效果,以及其对前房(AC)形态是否有影响。

方法

回顾性分析接受5-0或6-0聚丙烯缝线GATT治疗的原发性开角型青光眼或剥脱性青光眼患者的病历记录。患者分为两组(5-0聚丙烯缝线GATT组:第1组 vs. 6-0聚丙烯缝线GATT组:第2组)。比较两组患者术前、术后第1、3和6个月时GATT的临床效果、眼压(IOP)值,以及使用Pentacam HR眼前节分析系统测量的参数,包括前房角(ACA)、前房深度(ACD)、前房容积(ACV)、中央角膜厚度(CCT)和瞳孔直径(PD)。

结果

本研究共纳入41例患者(第1组:n = 21,第2组:n = 20)。两组患者的眼压均降低了约60%,且每次随访时眼压降低率在两组间相似(所有p>0.05)。确定两组在任何一次随访时,包括ACA、ACD、ACV、CCT和PD在内的前房参数均无差异(所有p>0.05)。此外,两组间的并发症发生率也无显著差异。

结论

观察到使用5-0或6-0聚丙烯缝线进行GATT在成功率、并发症发生率以及对前房形态的影响方面均无显著差异。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验