Abstract

PURPOSE

The VIABAHN VBX is a versatile stent graft that can be overdilated by up to 30% of its nominal diameter. However, to reach its maximum diameter, the balloon must be exchanged for a larger one. This technical note aims to illustrate a technique designed to enhance accuracy during the deployment and overdilation of a VIABAHN VBX for treating an injury to the left innominate vein (LIV).

TECHNIQUE

Two venous accesses were established in the left arm and in the right femoral vein. Using a rendezvous technique, a hydrophilic guidewire was snared and externalized from the arm. The balloon-expandable stent was advanced through the brachial access, and the larger balloon from the femoral access, both on the same guidewire. The balloon-expandable stent was inflated to its maximum diameter. During the retraction of the first balloon, the larger balloon was then advanced within the stent graft to perform overdilation.

RESULTS

The defect in the LIV was sealed-off without stent-graft migration and the patient showed improvement in his clinical condition.

CONCLUSION

The VIABAHN VBX is a valid option for treating injuries to the LIV. The double-balloon on a single wire (double-BLOW) technique may be an advantageous approach to prevent migration and enhance accuracy during deployment.Clinical ImpactThe double-BLOW technique offers improved stability and enhanced precision in deliver stent grafts and it might be useful when a larger balloon is required to perform over dilatation.

摘要

目的

VIABAHN VBX是一种多功能覆膜支架,其可过度扩张至标称直径的30%。然而,要达到其最大直径,必须更换为更大尺寸的球囊。本技术说明旨在阐述一种技术,该技术旨在提高VIABAHN VBX在治疗左无名静脉(LIV)损伤时的展开和过度扩张过程中的准确性。

技术

在左臂和右股静脉建立两条静脉通路。采用会师技术,将一根亲水导丝从手臂圈套并引出体外。球囊扩张支架通过肱动脉通路推进,较大的球囊从股动脉通路推进,二者均在同一根导丝上。将球囊扩张支架膨胀至其最大直径。在回撤第一个球囊时,将较大的球囊推进至覆膜支架内进行过度扩张。

结果

LIV的缺损被封闭,覆膜支架无移位,患者临床状况改善。

结论

VIABAHN VBX是治疗LIV损伤的有效选择。单导丝双球囊(double-BLOW)技术可能是一种有利的方法,可防止移位并提高展开过程中的准确性。临床影响双球囊技术在输送覆膜支架时提供了更好的稳定性和更高的精度,当需要更大的球囊进行过度扩张时可能会很有用。