Suppr超能文献

14年后白榴石增强陶瓷嵌体/高嵌体的体内磨损分析

In Vivo Wear Analysis of Leucite-Reinforced Ceramic Inlays/Onlays After 14 Years.

作者信息

Matta Ragai-Edward, Berger Lara, Sednyev Oleksandr, Bäuerle Dennis, Maier Eva, Adler Werner, Taschner Michael

机构信息

Department of Prosthodontics, Erlangen University Hospital, Glueckstrasse 11, 91054 Erlangen, Germany.

Department of Operative Dentistry and Periodontology, Erlangen University Hospital, Glueckstrasse 11, 91054 Erlangen, Germany.

出版信息

Materials (Basel). 2025 Jul 23;18(15):3446. doi: 10.3390/ma18153446.

Abstract

Material wear significantly impacts the clinical success and longevity of dental ceramic restorations. This in vivo study aimed to assess the wear behavior of IPS Empress glass-ceramic inlays and onlays over 14 years, considering the influence of different antagonist materials. Fifty-four indirect restorations of 21 patients were available for comprehensive wear analysis, with complete follow-up data for up to 14 years. Three-dimensional measurements relied on digitized epoxy resin models produced immediately post-insertion (baseline) and subsequently at 2, 4, and 14 years. The occlusal region on the baseline model was delineated for comparative analysis. Three-dimensional superimpositions with models from subsequent time points were executed to assess wear in terms of average linear wear and volumetric loss. Statistical analyses were conducted in R (version 4.4.1), employing Mann-Whitney U tests (material comparisons) and Wilcoxon signed rank tests (time point comparisons), with a significance threshold of ≤ 0.05. During the entire study period, an increase in wear was observed at each assessment interval, gradually stabilizing over time. Significant differences in substance loss were found between the follow-up time points, both for mean (-0.536 ± 0.249 mm after 14a) and integrated distance (-18,935 ± 11,711 mm after 14a). In addition, significantly higher wear was observed after 14 years with gold as antagonist compared to other materials ( ≤ 0.03). The wear behavior of IPS Empress ceramics demonstrates clinically acceptable long-term outcomes, with abrasion characteristics exhibiting stabilization over time.

摘要

材料磨损对牙科陶瓷修复体的临床成功率和使用寿命有显著影响。这项体内研究旨在评估IPS Empress玻璃陶瓷嵌体和高嵌体在14年中的磨损行为,并考虑不同对抗材料的影响。21名患者的54个间接修复体可用于全面的磨损分析,有长达14年的完整随访数据。三维测量依赖于植入后立即(基线)以及随后在2年、4年和14年制作的数字化环氧树脂模型。在基线模型上划定咬合区域用于对比分析。与后续时间点的模型进行三维叠加,以根据平均线性磨损和体积损失评估磨损情况。在R(版本4.4.1)中进行统计分析,采用曼-惠特尼U检验(材料比较)和威尔科克森符号秩检验(时间点比较),显著性阈值≤0.05。在整个研究期间,每个评估间隔都观察到磨损增加,随着时间推移逐渐稳定。在随访时间点之间发现物质损失存在显著差异,无论是平均磨损(14年后为-0.536±0.249毫米)还是累计距离(14年后为-18,935±11,711毫米)。此外,与其他材料相比,14年后以金作为对抗材料时观察到的磨损显著更高(≤0.03)。IPS Empress陶瓷的磨损行为显示出临床上可接受的长期结果,磨损特征随时间推移呈现稳定状态。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1e7c/12347852/4b10aee2d623/materials-18-03446-g001.jpg