Moore Zoe M, Wood Grace, Elliott Jake, Simon Julianna C, Vidt Meghan E
Biomedical Engineering, Pennsylvania State University, University Park, PA, USA.
Graduate Program in Acoustics, Pennsylvania State University, University Park, PA, USA.
J Electromyogr Kinesiol. 2025 Aug 7;84:103043. doi: 10.1016/j.jelekin.2025.103043.
Tendinopathy is an overuse injury that occurs in high load bearing tendons, causing decreased function and increased pain. Current tendinopathy treatments produce inconsistent outcomes, creating a need for novel treatments. It is unclear whether current tendinopathy models used to develop new treatments replicate the mechanical effects of the injury. We aim to compare the mechanical properties of 2 established tendinopathy models - collagenase injection and mechanical overload - in ex vivo bovine tendons. Eighteen bovine tendons were split into 3 groups, including: uninjured, collagenase injection (0.5 mL collagenase and 0.5 mL fibrin gel), and mechanical overload (5 cycles of tensile loading/unloading). Mechanical testing of samples was performed. Stiffness, maximum force at failure, and ultimate tensile stress (UTS) were computed, then compared across groups using 1-way ANOVA with significance set at p < 0.05. Results showed maximum force and UTS were reduced for the mechanical overload group (402.1 ± 232.3 N; 9.1 ± 5.3 MPa) versus uninjured (1222.9 ± 270.8 N; 28.9 ± 4.6 MPa) and collagenase injection groups (1309.0 ± 242.1 N; 25.0 ± 8.2 MPa) (all p < 0.001). Stiffness was not different across groups (all p > 0.33). Findings suggest that ex vivo mechanical overload better represents the mechanical properties of tendinopathy than collagenase injection.
肌腱病是一种发生在高负荷承受肌腱的过度使用损伤,会导致功能下降和疼痛加剧。目前的肌腱病治疗方法效果不一,因此需要新的治疗方法。目前用于开发新治疗方法的肌腱病模型是否能复制损伤的力学效应尚不清楚。我们旨在比较两种已建立的肌腱病模型——胶原酶注射和机械过载——在体外牛肌腱中的力学性能。18根牛肌腱被分为3组,包括:未受伤组、胶原酶注射组(0.5毫升胶原酶和0.5毫升纤维蛋白凝胶)和机械过载组(5个拉伸加载/卸载循环)。对样本进行力学测试。计算刚度、破坏时的最大力和极限拉伸应力(UTS),然后使用单因素方差分析在各组之间进行比较,显著性设定为p < 0.05。结果显示,与未受伤组(1222.9 ± 270.8 N;28.9 ± 4.6 MPa)和胶原酶注射组(1309.0 ± 242.1 N;25.0 ± 8.2 MPa)相比,机械过载组的最大力和UTS降低(402.1 ± 232.3 N;9.1 ± 5.3 MPa)(所有p < 0.001)。各组之间的刚度没有差异(所有p > 0.33)。研究结果表明,体外机械过载比胶原酶注射更能代表肌腱病的力学性能。