The results of tests with physical load on a bicycle ergometer and treadmill in 50 patients with ischemic heart disease were compared. The control group was formed of 20 patients with neurocirculatory dystonia. Agreement between the results of both tests was encountered in 90% of patients with ischemic heart disease. The authors conclude that the tests do not differ essentially in the main indices (rate of cardiac contractions, index of cardiac activity at the peak of the load, time of uninterrupted work until the criteria of load cessation). It is suggested that tests on the treadmill and those on the bicycle ergometer in patients with ischemic heart disease are equivalent.

摘要

对50例缺血性心脏病患者在自行车测力计和跑步机上进行体力负荷测试的结果进行了比较。对照组由20例神经循环性肌张力障碍患者组成。在90%的缺血性心脏病患者中,两种测试结果存在一致性。作者得出结论,两种测试在主要指标(心脏收缩率、负荷峰值时的心脏活动指数、直至负荷停止标准的不间断工作时间)上没有本质区别。建议对缺血性心脏病患者在跑步机上和在自行车测力计上进行的测试是等效的。