Rowe R C
J Pharm Pharmacol. 1981 Jan;33(1):1-4. doi: 10.1111/j.2042-7158.1981.tb13690.x.
The effect of the particle size of a model inert additive--a dolomite, commercially available in a wide range of grades with varying particle sizes--on the surface roughness of a coated tablet has been studied using a stylus surface roughness measuring instrument. With all grades with a maximum particle size below 10-15 microns there was only a marginal increase in roughness on the addition of the material at low concentrations with a marked increase at concentrations in excess of 20-30% v/v. With the largest particle size material (mean size 18 microns) there was a marked increase in surface roughness at low concentrations with a decrease at higher concentrations. The different trends were due to the influence of the inherent roughness of the tablet substrate used. The results illustrate the potential of this accurate, rapid, simple and non-destructive technique in the optimization of film formulations during product development.
使用触针式表面粗糙度测量仪,研究了一种模型惰性添加剂——白云石(有多种不同粒径等级的市售产品)的粒径对包衣片剂表面粗糙度的影响。对于所有最大粒径低于10 - 15微米的等级,在低浓度添加该材料时,粗糙度仅有轻微增加,而在浓度超过20 - 30% v/v时显著增加。对于最大粒径的材料(平均粒径18微米),在低浓度时表面粗糙度显著增加,而在较高浓度时降低。这些不同的趋势是由于所用片剂基质固有粗糙度的影响。结果表明了这种准确、快速、简单且无损的技术在产品开发过程中优化薄膜配方方面的潜力。